Frigidaire fes368dsc Manuel De Montage

Page de 28
1
30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
G. Minimum cutout depth is increased to 24" (61 cm) with backguard.
 P/N 318201606 (0311) Rev. B
English – pages 1-9
Español – páginas 10-18
Français – pages 19-27
** For cutouts below
22 7/8"(58.1 cm),
appliance will
slightly show out
of the cabinet.
***
IMPORTANT
:
For width cutout (F dimension) more than 30 1/16"
(76.4 cm) to avoid glass breakage, make sure the
appliance is center in the counter opening. Raise
leveling legs at maximum position, insert the appliance
in the counter and then level. Make sure the unit is
supported by the leveling legs not by the smoothtop
glass itself.
35 3/8" (90 cm) - 36 3/8" (92 cm)
30" (76,2 cm)
28 5/16" (71,9 cm)
30 ± 1/16"
(76,2 ± 0,15 cm)
21 3/4" (55,2 cm) Min.
22 1/8" (56,2 cm) Max.
36" (91,4 cm) standard
35 3/8" (90 cm) min.
A. HEIGHT
B.WIDTH
C. DEPTH
TO FRONT
OF RANGE
F. CUTOUT
WIDTH***
G. CUTOUT
DEPTH
H. HEIGHT
OF
COUNTERTOP
Do not pinch the power
supply cord between the
range and the wall.
Do not seal the range to the
side cabinets.
* NOTE: 24" (61 cm)
minimum clearance
between the cooktop and
the bottom of the cabinet
when the bottom of wood
or metal cabinet is
protected by not less than
1/4" (0.64 cm) flame
retardant millboard
covered with not less than
No. 28 MSG sheet metal,
0.015" (0.4 mm) stainless
steel, 0.024" (0.6 mm)
aluminum, or 0.020" (0.5
mm) copper.
30" (76.2 cm) minimum
clearance when the
cabinet is unprotected.
• Door Open
(see note)
1 5/16"
(3.3 cm)
C
21 3/4"
(55.25 cm)
A
B
NOTE: Allow at least 19 ¼" (48.9 cm) clearance for
door depth when it is open.
1 1/8"
(2.86 cm)
22 7/8"**
(58.1 cm) min.
23 1/4"**
(59.05 cm) max.
FRONT
OF
CABINET
G
   Ref.
NOTE:
 For 29" (73.7 cm) cutout wide
opening, you must call for optional
side panels and clear wide cooktop
rim as shown in the "Countertop
Preparation
" section (see page 6).
Shave Raised
Edge To Clear
31 1/2"(81cm)
Wide Cooktop
Rim.
1 ½" Max.
(3.8 cm Max.)
Grounded Junction Box or Wall Outlet Should Be
Located 8" to 17" (20.3 - 43.2 cm) From Right
Cabinet and 2" to 4" (5.1-10.2 cm) From Floor
18" Min.
(45.7 cm) Min.
24" Min.
(61 cm) Min.
Approx. 1 7/8"
(4.8 cm)
G
H
F
30" Min.
(76.2 cm) Min.
30" Min.*
(76.2 cm) Min.*
13"
(33 cm)
Locate Cabinet Doors
1" (2.5 cm) Min.
From Cutout Opening