Extreme 3802 Manuel Du Matériel Informatique

Page de 352
 
138
Extreme Networks Consolidated Hardware Guide
Alpine 3800 Series Switch Power Supplies
1 All installation, maintenance, and removal of a power supply must be done by qualified, trained service personnel only. 
2 If you have one AC power supply installed in the Alpine 3802 switch, it must be installed in the lower power supply tray 
(PSU A).
3 If you require DC power supplies in the Alpine 3802 switch, you must have two DC power supplies installed. 
The Alpine 3800 series switch generates SNMP traps for the following events:
AC power source fails
Power supply fails
Power supply is removed
For more information about planning your site and power requirements, see “Meeting Power 
Requirements” in 
Chapter 2. For more information about the specifications of the Alpine 3800 series 
switch power supplies, see Table 95 on page 312.
Power Supply LEDs
Table 39 and Table 40 describe LEDs that pertain to power for the Alpine 3800 series switch.
Table 38: Supported power supplies for the Alpine 3800 series switch
Switch Model
AC Power Supply
DC Power Supply
Hot-swappable
Alpine 3808
1
Up to two AC power 
supplies can be installed.
Up to two DC power 
supplies can be installed.
Yes
Alpine 3804
1
Up to two AC power 
supplies can be installed.
Up to two DC power 
supplies can be installed.
Yes
Alpine 3802
1
Up to two AC power 
supplies can be installed.
2
Two DC power supplies 
must be installed.
3
No
Table 39: Alpine 3808 and Alpine 3804 power supply LED
LED
Color
Indicates
D/C OK
Green
Off
All DC outputs are operational
One or more DC outputs have failed
Table 40: Alpine 3802 power supply LED  
LED
Color
Indicates
PSU A, PSU B Green
Amber
Off
Normal operation
DC output failure
PSU not present or not powered