Chapter 6—Configuration Command Reference 
Trakker Antares 2400 Family System Manual 
157 
For the Donation ID Number or the National Use Bar Code, scan an 
alphanumeric bar code from the “Full ASCII Bar Code Chart” on page 
284. 
•  For the Donation ID Number, scan a value from 0 through 9 or 
uppercase A through Z. 
•  For the National Use Bar Code, scan a value from lowercase a 
through z. 
If you want to keep the default concatenation control parameters, go to 
Step 10. 
•  The default concatenation distance is 16 mm 
± 0 mm. 
•  The default concatenation decode time limit is 160 ms. 
If you want to set the concatenation control parameters, follow these 
instructions: 
•  To set the concatenation decode time limit, scan these bar codes to 
set the time from 001 to 999 ms. 
•  To set the concatenation distance, scan these bar codes to set the 
distance from 00 to 99 mm and the tolerance from 
± 1 to 9 mm. 
 
*0* 
*1* 
 *0* 
*1* 
 
*2* 
*3* 
 *2* 
*3* 
 
*4* 
*5* 
 *4* 
*5* 
 
 
*6* 
*7* 
 *6* 
*7* 
 
*8* 
*9* 
 *8* 
*9* 
Scan one of these bar codes to set the concatenation distance or time 
limit: 
 Distance 
Time 
 
*+D* 
*+T* 
 *d* 
*t* 
10 
Scan this bar code: 
  Exit Accumulate Mode 
 
*-/* 
 *-/*