Product Dimensions
Installation Clearances
Cabinet opening dimensions shown are for 25" (64 cm) 
countertop depth, 24" (61 cm) base cabinet depth and
36" (91.4 cm) countertop height.
*NOTE: 24" (61 cm) minimum when bottom of wood or metal 
cabinet is protected by not less than 
¹⁄₄" (0.64 cm) flame retardant 
millboard covered with not less than No. 28 MSG sheet steel, 
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking 
platform and the bottom of an unprotected wood or metal 
cabinet.
Electrical Requirements
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from: 
National Fire Protection Association, One Batterymarch Park, 
Quincy, MA 02269.
Electrical Connection
To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
Range must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating 
plate. (The model/serial number rating plate is located on the 
oven frame behind the storage drawer panel.)
When a 4-wire or 3-wire, single phase 120/240 volt, 60 Hz, AC 
only electrical supply is available (or, if specified on the model/
serial rating plate, when a 4-wire or 3-wire single phase 
120/208 volt 60 Hz, AC only electrical supply is available), a 
40- or 50-amp maximum circuit protection is required, fused 
on both sides of the line.
A time-delay fuse or circuit breaker is recommended.
The range can be connected directly to the fused disconnect 
(or circuit breaker box) through flexible, armored or 
nonmetallic sheathed, copper or aluminum cable. See 
“Electrical Connection.”
Allow 2 to 3 ft of slack in the line so that the range can be 
moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end 
of the power supply cable (at the range and at the junction 
box).
Wire sizes and connections must conform with the rating of 
the range.
The wiring diagram is located on the back of the range or 
inside the storage drawer in a clear plastic bag.
A. 27
¹⁄₈
" (68.9 cm) depth with handle
28
¹⁄₈
" (71.6 cm) depth with handle (KitchenAid models only)
B. 46
⁷⁄₈
" (119.1 cm) overall height
46" (116.8 cm) overall height (KitchenAid models only)
C. 36" (91.4 cm) cooktop height
D. 29
⁷⁄₈
" (75.9 cm) width
E. 24
¹³⁄₁₆
" (63 cm) depth
A. 4" (10.2 cm) min. clearance from both sides of range to side wall or 
other combustible material
B. 18" (45.7 cm) upper side cabinet to countertop
C. 13" (33 cm) max. upper cabinet depth
D. 30" (76.2 cm) min. opening width
E. For minimum clearance to top of cooktop, see NOTE*.
F. 30" (76.2 cm) min. opening width
G. Outlet - 8" (20.3 cm) to 22" (55.9 cm) from either cabinet,
5
¹⁄₂
" (14.0 cm) max. from floor
H.
⁷⁄₈
" (2.2 cm) min. required between cutout and cabinet door or hinge
A
B
C
D
E
A
B
C
D
E
F
G
H
E