the bottom of the charging slot. Always connect the cells in the right direction for polarity 
(according  to  the  symbols  in  the  charging  slots).  The  cells  do  not  have  to  be  inserted 
simultaneously as the charging processes are separate from each other. 
To prevent the cylindrical cells and the 9 V block from overcharging please only charge empty 
cells. Please note the charging times in the table (6). 
The maximum charging time for empty cells can be calculated with following formula:
Charging time (h)  =  
1.4 (charging factor) x capacity (mAh)
                                                      charge current (mA)
EXAMPLE: 
Mignon AA 2000 mAh   charging current for AA cells:150 mA
 
 
                  1.4 x 2000 mAh    
   
 
                       150 mA
 
                                Charging time: approx. 18.5 h
MAINTENANCE AND CLEANING:
To clean the charger, disconnect it from the power adaptor. To ensure correct function of the 
charger keep the charging contacts free from dust and dirt. Please only use a dry cloth.
ENVIRONMENT:
Rechargeable batteries are not to be disposed of in domestic waste. Used batteries should be 
turned into a battery recycling collection depot. Check with your local municipal office.
TECHNICAL DATA:
Charging current: Micro AAA: 50 mA; Mignon AA: 150 mA; Baby C: 200 mA; Mono D: 200 
mA; 9V: 15 mA