GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to 
Natural gas must be done by a qualified installer. 
LP Gas Conversion
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Remove oven racks from inside the oven cavity.
2. Remove the storage drawer. See “Replace Oven Racks and 
Storage Drawer” section.
3. Remove the oven door. See “Oven Door” section in the Use 
and Care Guide for oven door removal instructions.
4. Using a Phillips screwdriver, remove and set aside the 2 oven 
bake burner cover screws located at the rear of the oven.
5. Lift up and remove oven bake burner cover.
6. Remove the 2 oven bake burner screws and set aside.
7. Swing the oven bake burner to the side and lift it off the oven 
orifice and set aside.
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death 
or serious burns to children and adults.
A
B
C
A. Oven bake burner cover
B. Oven bake burner cover screws
A. Oven bake burner screws
B. Oven orifice
A
B
A
B
A