Whirlpool GW397LXU Manuel De Montage

Page de 36
8
4. Drill two 
¹⁄₈" (3 mm) holes that correspond to the bracket holes 
of the determined mounting method. See below.
Floor Mounting  
Wall Mounting
5. Using the Phillips screwdriver, mount anti-tip bracket to the 
wall or floor with the two #12 x 1
⁵⁄₈" screws provided.
Make Gas Connection
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and G in the following illustration). 
2. Attach one adapter to the gas pressure regulator and the other 
adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 
¹⁵⁄₁₆" combination wrench and an adjustable wrench to 
attach the flexible connector to the adapters. Check that 
connector is not kinked.   
A. #12 x 1
⁵⁄₈" screws
B. Anti-tip bracket
A. #12 x 1
⁵⁄₈" screws
B. Anti-tip bracket
A
B
A
B
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
D
E
F
G
H