Important Safety Information
WARNING: This device has more than one power input. Disconnect all 
power inputs to power off this device.
WARNING: The installation of the Redundant Power Supply (RPS) should 
only be carried out by properly trained and qualified personnel.
WARNING: These instructions must be read in conjunction with the RPS 
flyer and the safety and installation instructions supplied with your RPS.
WARNING: When powering any Switch 4500 from an RPS, the unit must 
be earthed (grounded). This can be achieved by either connecting the 
power cord to the unit or by connecting the earth terminal on the rear of 
the unit to a reliable electrical earth, or by connecting both. It must be 
ensured that the earth connection is made before connecting the DC 
supply from the RPS.
WARNING: Any RPS must be approved as an unearthed SELV output in 
accordance with IEC 60950-1/UL 60950-1/EN 60950-1.
WARNING: RPS Manufacturers’ recommendations must be followed 
when connecting the cable to the RPS.
WARNING: Ensure that the circuit breaker in the RPS is in the open (off) 
position when connecting the cable to the RPS. 
WARNING: You must ensure that the positive terminal on the Switch is 
connected to the positive (common) terminal of the RPS and that the 
negative terminal on the Switch is connected to the negative (circuit 
breaker) terminal of the RPS.