3com S7906E Manuel De Montage

Page de 2621
 
1-6 
Figure 1-3 Network diagram for configuring BPDU tunneling for STP 
 
 
Configuration procedure 
1)  Configuration on PE 1 
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.  
<PE1> system-view 
[PE1] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0 
# Create VLAN 2 and assign GigabitEthernet 2/0/1 to VLAN 2.  
[PE1] vlan 2 
[PE1-vlan2] quit 
[PE1] interface gigabitethernet 2/0/1 
[PE1-GigabitEthernet2/0/1] port access vlan 2 
# Disable STP on GigabitEthernet 2/0/1, and then enable BPDU tunneling for STP on it.  
[PE1-GigabitEthernet2/0/1] undo stp enable 
[PE1-GigabitEthernet2/0/1] bpdu-tunnel dot1q stp 
2)  Configuration on PE 2 
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.  
<PE2> system-view 
[PE2] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0 
# Create VLAN 2 and assign GigabitEthernet 2/0/2 to VLAN 2.  
[PE2] vlan 2 
[PE2-vlan2] quit 
[PE2] interface gigabitethernet 2/0/2 
[PE2-GigabitEthernet2/0/2] port access vlan 2 
# Disable STP on GigabitEthernet 2/0/2, and then enable BPDU tunneling for STP on it. 
[PE2-GigabitEthernet2/0/2] undo stp enable 
[PE2-GigabitEthernet2/0/2] bpdu-tunnel dot1q stp 
BPDU Tunneling for PVST Configuration Example 
Network requirements 
As shown in 
CE 1 and CE 2 are edges devices on the geographically dispersed network of User A; PE 1 and PE 
2 are edge devices on the service provider network.