3com S7906E Manuel De Montage

Page de 2621
 
3-19 
Network diagram 
Figure 3-1 
Network diagram for ONU port-to-ONU binding configuration 
ONU1
OLT
OLT3/0/1
POS
ONU2
 
 
Configuration procedure 
# Configure the OUI and extended OAM version number list.  
<Sysname> system-view 
System View: return to User View with Ctrl+Z. 
[Sysname] ftth 
[Sysname-ftth] epon-parameter ouilist oui 000fe2 oam-version 2  slot 3  
[Sysname-ftth] quit 
# Create ONU ports ONU 3/0/1:1 and ONU 3/0/1:2. Bind ONU 3/0/1:1 to the ONU 1 and ONU 3/0/1:2 to 
ONU 2.  
[Sysname] interface olt 3/0/1 
[Sysname-Olt3/0/1] using onu 1 to 2 
[Sysname-Olt3/0/1] quit 
[Sysname] interface onu 3/0/1:1 
[Sysname-Onu3/0/1:1] bind onuid 000f-e200-0031 
[Sysname-Onu3/0/1:1] quit 
[Sysname] interface onu 3/0/1:2 
[Sysname-Onu3/0/1:2] bind onuid 000f-e200-3749 
# When the two ONUs are up, display the binding information of the ONUs.  
<Sysname> display onuinfo interface Olt 3/0/1 
ONU Mac Address LLID Dist(M)         Port    Board/Ver  Sft/Epm   State  Aging 
 000f-e200-0031     1     <50   Onu3/0/1:1  ET704-A-L/B  110/100      Up    N/A 
 000f-e200-3749     2     <50   Onu3/0/1:2  ET704-A-L/B  110/100      Up    N/A 
 
 ---  2 entries found  --- 
ONU RSTP Configuration Example 
Network requirements 
 
A user PC is attached to UNI 1. If UNI 2 and UNI 3 are interconnected by mistake while RSTP is 
disabled on the ONU, broadcast storm will occur between UNI 2 and UNI 3 when the user pings an 
IP address for which no ARP entry exists on the PC.