# Specify the DNS server 2.1.1.2. 
[SwitchB] dns server 2.1.1.2 
4) Configuration 
verification 
# Execute the ping host.com command on Switch B to verify that the communication between the 
Switch and the host is normal and that the corresponding destination IP address is 3.1.1.1. 
[SwitchB] ping host.com 
Trying DNS resolve, press CTRL_C to break 
 Trying DNS server (2.1.1.2) 
  PING host.com (3.1.1.1): 
  56  data bytes, press CTRL_C to break 
    Reply from 3.1.1.1: bytes=56 Sequence=1 ttl=126 time=3 ms 
    Reply from 3.1.1.1: bytes=56 Sequence=2 ttl=126 time=1 ms 
    Reply from 3.1.1.1: bytes=56 Sequence=3 ttl=126 time=1 ms 
    Reply from 3.1.1.1: bytes=56 Sequence=4 ttl=126 time=1 ms 
    Reply from 3.1.1.1: bytes=56 Sequence=5 ttl=126 time=1 ms 
 
  --- host.com ping statistics --- 
    5 packet(s) transmitted 
    5 packet(s) received 
    0.00% packet loss 
    round-trip min/avg/max = 1/1/3 ms 
Troubleshooting IPv4 DNS Configuration 
Symptom 
After enabling the dynamic domain name resolution, the user cannot get the correct IP address. 
Solution 
Use the display dns dynamic-host command to verify that the specified domain name is in the 
cache. 
If the specified domain name does not exist, check that dynamic domain name resolution is 
enabled and the DNS client can communicate with the DNS server. 
If the specified domain name is in the cache, but the IP address is incorrect, check that the DNS 
client has the correct IP address of the DNS server. 
Verify the mapping between the domain name and IP address is correct on the DNS server.