3com S7906E Guide De Référence

Page de 2327
 
1-30 
undo timer other-querier-present 
View 
Public instance IGMP view, VPN instance IGMP view  
Default Level 
2: System level 
Parameters 
interval: IGMP other querier present interval, in the range of 60 to 300.  
Description 
Use the timer other-querier-present command to configure the IGMP other querier present interval 
globally.  
Use the undo timer other-querier-present command to restore the system default.  
By default, the IGMP other querier present interval is [ IGMP query interval ] times [ IGMP querier 
robustness variable ] plus [ maximum response time for IGMP general queries ] divided by two.  
 
  
By default, the three parameters in the above-mentioned formula are 60 (seconds), 2 (times) and 10 
(seconds) respectively, so the IGMP other querier present interval = 60 × 2 + 10 / 2 = 125 (seconds).  
 
Related commands: igmp timer other-querier-present
timer query
robust-count
max-response-timedisplay igmp interface.  
Examples 
# Set the IGMP other querier present interval to 200 seconds globally in the public instance.  
<Sysname> system-view 
[Sysname] igmp 
[Sysname-igmp] timer other-querier-present 200 
timer query (IGMP view) 
Syntax 
timer query interval 
undo timer query 
View 
Public instance IGMP view, VPN instance IGMP view  
Default Level 
2: System level