3com S7906E Guide De Référence

Page de 2327
 
1-31 
Parameters 
interval: IGMP query interval in seconds, namely interval between IGMP general queries, with an 
effective range of 1 to 18,000.  
Description 
Use the timer query command to configure the IGMP query interval globally.  
Use the undo timer query command to restore the default setting.  
By default, IGMP query interval is 60 seconds.  
Related commands: igmp timer querytimer other-querier-presentdisplay igmp interface.  
Examples 
# Set the IGMP query interval to 125 seconds globally in the public instance. 
<Sysname> system-view 
[Sysname] igmp 
[Sysname-igmp] timer query 125 
version (IGMP view) 
Syntax 
version version-number 
undo version 
View 
Public instance IGMP view, VPN instance IGMP view  
Default Level 
2: System level 
Parameters 
version-number: IGMP version, in the range of 1 to 3.  
Description 
Use the version command to configure the IGMP version globally.  
Use the undo version command to restore the system default.  
The default IGMP version is version 2. 
Related commands: igmp version.  
Examples 
# Set the global IGMP version to IGMPv1 in the public instance.  
<Sysname> system-view 
[Sysname] igmp 
[Sysname-igmp] version 1