3com S7906E Guide De Référence

Page de 2327
 
2-2 
dot1x timer ead-timeout 
Syntax 
dot1x timer ead-timeout ead-timeout-value 
undo dot1x timer ead-timeout 
View 
System view  
Default Level 
2: System level  
Parameters 
ead-timeout-value: EAD rule timeout time, in the range 1 minute to 1440 minutes.  
Description 
Use the dot1x timer ead-timeout command to set the EAD rule timeout time.  
Use the undo dot1x timer ead-timeout command to restore the default.  
By default, the timeout time is 30 minutes.  
Related commands: display dot1x
Examples 
# Set the EAD rule timeout time to 5 minutes. 
<Sysname> system-view 
[Sysname] dot1x timer ead-timeout 5 
dot1x url 
Syntax 
dot1x url url-string 
undo dot1x url-string 
View 
System view 
Default Level 
2: System level  
Parameters 
url-string: Redirect URL, a case-sensitive string of 1 to 64 characters in the format http://string/. 
Description 
Use the dot1x url command to configure a redirect URL. After a redirect URL is configured, when a 
user uses a Web browser to access networks other than the free IP, the device will redirect the user to 
the redirect URL.  
Use the undo dot1x url command to remove the redirect URL.