3com S7906E Guide De Référence
1-17
Field
Description
RX power low
Incoming (RX) power level is low.
display transceiver diagnosis
Syntax
display transceiver diagnosis interface [ interface-type interface-number ]
View
Any view
Default Level
2: System level
Parameters
interface [ interface-type interface-number ]: Displays the currently measured value of digital diagnosis
parameters of the H3C customized anti-spoofing pluggable optical transceiver plugged in the specified
interface. interface-type interface-number represents interface type and interface number. If it is not
specified, the command displays the currently measured value of digital diagnosis parameters of H3C
customized anti-spoofing pluggable optical transceivers in all the interfaces.
Description
Use the display transceiver diagnosis command to display the currently measured value of digital
diagnosis parameters of H3C customized anti-spoofing pluggable optical transceivers.
Examples
# Display the currently measured value of the digital diagnosis parameters of the H3C customized
anti-spoofing pluggable optical transceiver plugged in interface GigabitEthernet 2/0/2.
<Sysname> display transceiver diagnosis interface gigabitethernet 2/0/2
GigabitEthernet2/0/2 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36 3.31 6.13 -35.64 -5.19
Table 1-7 display transceiver diagnosis command output description
Field
Description
transceiver diagnostic information
Digital diagnosis information of the transceiver
plugged in the interface
plugged in the interface
Current diagnostic parameters
Current diagnostic parameters
Temp.(°C)
Digital diagnosis parameter-temperature, in °C,
with the precision to 1°C.
with the precision to 1°C.
Voltage(V)
Digital diagnosis parameter-voltage, in V, with the
precision to 0.01 V.
precision to 0.01 V.
Bias(mA)
Digital diagnosis parameter-bias current, in mA,
with the precision to 0.01 mA.
with the precision to 0.01 mA.