3com S7906E Guide De Référence

Page de 2327
 
1-17 
Field 
Description 
RX power low 
Incoming (RX) power level is low. 
 
display transceiver diagnosis 
Syntax 
display transceiver diagnosis interface [ interface-type interface-number ]  
View 
Any view 
Default Level 
2: System level 
Parameters 
interface [ interface-type interface-number ]: Displays the currently measured value of digital diagnosis 
parameters of the H3C customized anti-spoofing pluggable optical transceiver plugged in the specified 
interface.  interface-type interface-number represents interface type and interface number. If it is not 
specified, the command displays the currently measured value of digital diagnosis parameters of H3C 
customized anti-spoofing pluggable optical transceivers in all the interfaces. 
Description 
Use the display transceiver diagnosis command to display the currently measured value of digital 
diagnosis parameters of H3C customized anti-spoofing pluggable optical transceivers. 
Examples 
# Display the currently measured value of the digital diagnosis parameters of the H3C customized 
anti-spoofing pluggable optical transceiver plugged in interface GigabitEthernet 2/0/2. 
<Sysname> display transceiver diagnosis interface gigabitethernet 2/0/2 
GigabitEthernet2/0/2 transceiver diagnostic information: 
  Current diagnostic parameters: 
    Temp(°C)  Voltage(V)  Bias(mA)  RX power(dBM)  TX power(dBM) 
    36        3.31        6.13      -35.64          -5.19 
Table 1-7 display transceiver diagnosis command output description 
Field 
Description 
transceiver diagnostic information 
Digital diagnosis information of the transceiver 
plugged in the interface 
Current diagnostic parameters 
Current diagnostic parameters 
Temp.(°C) 
Digital diagnosis parameter-temperature, in °C, 
with the precision to 1°C. 
Voltage(V) 
Digital diagnosis parameter-voltage, in V, with the 
precision to 0.01 V. 
Bias(mA) 
Digital diagnosis parameter-bias current, in mA, 
with the precision to 0.01 mA.