3com S7906E Guide De Référence

Page de 2327
 
1-21 
# Set the output channel for the log information of VLAN module to snmpagent and to output 
information with severity being emergencies. Log information of other modules and all the other 
system information cannot be output to this channel. 
<Sysname> system-view 
[Sysname] info-center source default channel snmpagent debug state off log state off trap 
state off 
[Sysname] info-center source vlan channel snmpagent log level emergencies state on 
info-center synchronous 
Syntax 
info-center synchronous 
undo info-center synchronous 
View 
System view 
Default Level 
2: System level 
Parameters 
None 
Description 
Use the info-center synchronous command to enable synchronous information output. 
Use the undo info-center synchronous command to disable the synchronous information output. 
By default, the synchronous information output is disabled. 
 
 
If system information, such as log information, is output before you input any information under a 
current command line prompt, the system will not display the command line prompt after the 
system information output. 
If system information is output when you are inputting some interactive information (non Y/N 
confirmation information), then after the system information output, the system will not display the 
command line prompt but your previous input in a new line. 
 
Examples 
# Enable the synchronous information output function, and then input the display interface ethe 
command to view Ethernet interface information. 
<Sysname> system-view 
[Sysname] info-center synchronous 
% Info-center synchronous output is on