Use the undo poe utilization-threshold command to restore the default power alarm threshold of 
the PSE. 
By default, the power alarm threshold for the PSE is 80%. 
The system sends a Trap message when the percentage of power utilization exceeds the alarm 
threshold. If the percentage of the power utilization always keeps above the alarm threshold, the 
system does not send any Trap message. Instead, when the percentage of the power utilization drops 
below the alarm threshold, the system sends a Trap message again. 
Examples 
# Set the power alarm threshold of PSE 7 to 90%. 
<Sysname> system-view 
[Sysname] poe utilization-threshold 90 pse 7 
poe-power input-threshold 
Syntax 
poe-power input-threshold { lower | upper } value 
undo poe-power input-threshold { lower | upper 
View 
System view 
Default Level 
2: System level 
Parameters 
lower value: Specifies an under-voltage threshold in volts. The under-voltage threshold range, default 
under-voltage threshold, and recommended under-voltage threshold vary with devices. 
upper value: Specifies an over-voltage threshold in volts. The over-voltage threshold range, default 
over-voltage threshold, and recommended over-voltage threshold vary with devices. 
Description 
Use the poe-power input-threshold command to configure an AC input under-voltage/over-voltage 
threshold. 
Use the undo poe-power input-threshold command to restore the default. 
The default AC input under-voltage/over-voltage threshold varies with devices. 
Examples 
# Set the AC input under-voltage threshold to 181 V. 
<Sysname> system-view 
[Sysname] poe-power input-threshold lower 181 
# Set the AC input over-voltage threshold to 264 V. 
<Sysname> system-view 
[Sysname] poe-power input-threshold upper 264