3com S7906E Guide De Référence

Page de 2327
 
1-35 
poe-power output-threshold 
Syntax 
poe-power output-threshold lower | upper value 
undo poe-power output-threshold { lower upper 
View 
System view 
Default Level 
2: System level 
Parameters 
lower value: Specifies an under-voltage threshold in volts. The under-voltage threshold range, default 
under-voltage threshold, and recommended under-voltage threshold vary with devices. 
upper value: Specifies an over-voltage threshold in volts. The over-voltage threshold range, default 
over-voltage threshold, and recommended over-voltage threshold vary with devices. 
Description 
Use the poe-power output-threshold command to configure a DC output under-voltage/over-voltage 
threshold. 
Use the undo poe-power output-threshold command to restore the default. 
The default DC output under-voltage/over-voltage threshold varies with devices. 
Examples 
# Set a DC output under-voltage threshold to 45 V. 
<Sysname> system-view 
[Sysname] poe-power output-threshold lower 45 
# Set a DC output over-voltage threshold to 57 V. 
<Sysname> system-view 
[Sysname] poe-power output-threshold upper 57 
poe-profile 
Syntax 
poe-profile profile-name [ index ] 
undo poe-profile { index index name profile-name 
View 
System view 
Default Level 
2: System level