3com S7906E Guide De Référence
1-35
poe-power output-threshold
Syntax
poe-power output-threshold { lower | upper } value
undo poe-power output-threshold { lower | upper }
View
System view
Default Level
2: System level
Parameters
lower value: Specifies an under-voltage threshold in volts. The under-voltage threshold range, default
under-voltage threshold, and recommended under-voltage threshold vary with devices.
upper value: Specifies an over-voltage threshold in volts. The over-voltage threshold range, default
over-voltage threshold, and recommended over-voltage threshold vary with devices.
Description
Use the poe-power output-threshold command to configure a DC output under-voltage/over-voltage
threshold.
Use the undo poe-power output-threshold command to restore the default.
The default DC output under-voltage/over-voltage threshold varies with devices.
Examples
# Set a DC output under-voltage threshold to 45 V.
<Sysname> system-view
[Sysname] poe-power output-threshold lower 45
# Set a DC output over-voltage threshold to 57 V.
<Sysname> system-view
[Sysname] poe-power output-threshold upper 57
poe-profile
Syntax
poe-profile profile-name [ index ]
undo poe-profile { index index | name profile-name }
View
System view
Default Level
2: System level