3com S7906E Guide De Référence

Page de 2327
 
1-20 
[Sysname-nqa-admin-test] type dhcp 
[Syaname-nqa-admin-test-dhcp] probe timeout 10000 
reaction 
Syntax 
reaction  item-num  checked-element probe-fail threshold-type consecutive occurrences 
action-type { none | trigger-only } ] 
undo reaction item-num 
View 
DHCP, DLSw, FTP, HTTP, ICMP-echo, SNMP, TCP, UDP-echo test type view 
Default Level 
2: System level 
Parameters 
item-num: Number of the reaction entry, in the range 1 to 10. 
checked-element: Type of the monitored element in collaboration. At present, the type of the 
monitored element can be probe failure only. 
probe-fail: The type of the monitored element is probe failure. 
threshold-type consecutive: Threshold type is consecutive probe failures. 
occurrences: Number of consecutive probe failures, in the range 1 to 16. 
action-type: Triggered action type, defaulting to none
none: No actions. 
trigger-only: Triggers collaboration between other modules only. 
Description 
Use the reaction command to establish a collaboration entry to monitor the probe results of the current 
test group. If the number of consecutive probe failures reaches the threshold, collaboration with other 
modules is triggered. 
Use the undo reaction command to remove the collaboration entry. 
By default, no collaboration entries are configured. 
Note that you cannot modify the content of a collaboration object using the reaction command after the 
collaboration object is created. 
Related commands: track in the Track Commands in the System Volume
Examples 
# Create collaboration object 1. If the number of consecutive probe failures reaches 3, collaboration 
with other modules is triggered. 
<Sysname> system-view 
[Sysname] nqa entry admin test 
[Sysname-nqa-admin-test] type tcp