cfd cc enable 
Syntax 
cfd cc service-instance instance-id mep mep-id enable 
undo cfd cc service-instance instance-id mep mep-id enable 
View 
Ethernet interface view 
Default level 
2: System level 
Parameters 
service-instance instance-id: Specifies the service instance ID, ranging from 1 to 32767. 
mep mep-id: Specifies the ID of an MEP, ranging from 1 to 8191. 
Description 
Use the cfd cc enable command to enable CCM sending on a specified MEP. 
Use the undo cfd cc enable command to cancel the configuration. 
By default, the CCM sending function is disabled. 
Related commands: cfd cc interval
Examples 
# On port GigabitEthernet 2/0/1, Enable CCM sending on service point 3.  
<Sysname> system-view 
[Sysname] interface GigabitEthernet 2/0/1 
[Sysname-GigabitEthernet2/0/1] cfd cc service-instance 5 mep 3 enable 
cfd cc interval 
Syntax 
cfd cc interval interval-field-value service-instance instance-id 
undo cfd cc interval service-instance instance-id