3com S7906E Guide De Référence
1-1
1
Connectivity Fault Detection Configuration
Commands
Connectivity Fault Detection Configuration Commands
cfd cc enable
Syntax
cfd cc service-instance instance-id mep mep-id enable
undo cfd cc service-instance instance-id mep mep-id enable
View
Ethernet interface view
Default level
2: System level
Parameters
service-instance instance-id: Specifies the service instance ID, ranging from 1 to 32767.
mep mep-id: Specifies the ID of an MEP, ranging from 1 to 8191.
Description
Use the cfd cc enable command to enable CCM sending on a specified MEP.
Use the undo cfd cc enable command to cancel the configuration.
By default, the CCM sending function is disabled.
Related commands: cfd cc interval.
Examples
# On port GigabitEthernet 2/0/1, Enable CCM sending on service point 3.
<Sysname> system-view
[Sysname] interface GigabitEthernet 2/0/1
[Sysname-GigabitEthernet2/0/1] cfd cc service-instance 5 mep 3 enable
cfd cc interval
Syntax
cfd cc interval interval-field-value service-instance instance-id
undo cfd cc interval service-instance instance-id