3com S7906E Guide De Référence

Page de 2327
 
1-2 
View 
System view 
Default level 
2: System level 
Parameters 
interval-field-value: Value of the interval field in CCM messages, ranging from 5 to 7. 
service-instance instance-id: Specifies the service instance ID, ranging from 1 to 32767. 
Description 
Use the cfd cc interval command to set the value of the interval field in the CCM messages. 
Use the undo cfd cc interval command to restore the value to the default value. 
By default, the value of this field is 5 for all CCMs sent. 
The relationship between the interval field value in the CCM messages, the time interval to send CCM 
messages and the timeout time of the remote MEP is illustrated in 
Table 1-1 Relationship of interval field value, time interval for sending CCMs and timeout time of 
remote MEP 
Interval field value 
Time interval for CCM 
Timeout time of remote MEP 
1 second 
3.5 seconds 
10 seconds 
35 seconds 
60 seconds 
210 seconds 
 
Related commands: cfd cc enable
Examples 
# Set the value of the interval field in CCMs to 7. 
<Sysname> system-view 
[Sysname] cfd cc interval 7 service-instance 2 
cfd enable 
Syntax 
cfd enable 
undo cfd enable 
View 
System view 
Default level 
2: System level