3com S7906E Guide De Référence
1-7
Examples
# Create an MA.
<Sysname> system-view
[Sysname] cfd md test_md level 3
[Sysname] cfd ma test_ma md test_md vlan 100
cfd md
Syntax
cfd md md-name level level-value
undo cfd md md-name
View
System view
Default level
2: System level
Parameters
md-name: Name of an MD, a string of 1 to 48 characters, composed of letters, numbers or underlines,
but cannot start with an underline character.
level level-value: Specifies an MD level, ranging from 0 to 7.
Description
Use the cfd md command to create an MD.
Use the undo cfd md command to delete an MD.
By default, no MD is created.
Note that:
z
You can create only one MD with a specific level. MD cannot be created if you enter an invalid MD
name or an existing MD name.
z
When deleting an MD, you will also delete the configurations related to that MD.
Examples
# Create an MD.
<Sysname> system-view
[Sysname] cfd md test_md level 3
cfd mep
Syntax
cfd mep mep-id service-instance instance-id { inbound | outbound }
undo cfd mep mep-id service-instance instance-id
View
Ethernet interface view