3com S7906E Guide De Référence

Page de 2327
 
1-7 
Examples 
# Create an MA. 
<Sysname> system-view 
[Sysname] cfd md test_md level 3 
[Sysname] cfd ma test_ma md test_md vlan 100 
cfd md 
Syntax 
cfd md md-name level level-value 
undo cfd md md-name 
View 
System view 
Default level 
2: System level 
Parameters 
md-name: Name of an MD, a string of 1 to 48 characters, composed of letters, numbers or underlines, 
but cannot start with an underline character. 
level level-value: Specifies an MD level, ranging from 0 to 7. 
Description 
Use the cfd md command to create an MD. 
Use the undo cfd md command to delete an MD. 
By default, no MD is created. 
Note that: 
You can create only one MD with a specific level. MD cannot be created if you enter an invalid MD 
name or an existing MD name. 
When deleting an MD, you will also delete the configurations related to that MD. 
Examples 
# Create an MD. 
<Sysname> system-view 
[Sysname] cfd md test_md level 3 
cfd mep 
Syntax 
cfd mep mep-id service-instance instance-id { inbound | outbound } 
undo cfd mep mep-id service-instance instance-id 
View 
Ethernet interface view