3com S7906E Guide De Référence
1-13
Field
Description
Relay Action
z
Found: Indicates that the forwarding device found the destination MAC
address in its MAC address table.
address in its MAC address table.
z
Unknown: Indicates that the forwarding device failed to find the
destination MAC address in its MAC address table.
destination MAC address in its MAC address table.
z
None: Indicates that it is a MEP that responded to the LTM message. A
MEP does not need to find the destination MAC address.
MEP does not need to find the destination MAC address.
display cfd linktrace-reply auto-detection
Syntax
display cfd linktrace-reply auto-detection [ size size-value ]
View
Any view
Default level
2: System level
Parameters
size size-value: Specifies the times of recent auto-detections, ranging from 1 to 100.
Description
Use the display cfd linktrace-reply auto-detection command to display the content of the LTR
messages received as responses to the automatically sent LTMs.
These LTR messages are stored in the buffer after you executed the cfd linktrace auto-detection
command. With the size parameter not specified, this command will display the information of all LTRs
stored in the buffer.
Examples
# Display the content of the LTRs received as responses to the LTMs sent.
<Sysname> display cfd linktrace-reply auto-detection
Service instance: 1 MEP ID: 1003 Time: 2006/05/22 10:43:57
Target MEP ID: 2005 TTL: 255
MAC Address TTL Forwarded Relay Action
00E0-FC27-6502 63 Yes Found
00E0-FC00-6510 62 Yes Found
00E0-FC52-BAA0 61 No None
Service instance: 2 MEP ID: 1023 Time: 2006/05/22 10:44:06
Target MEP ID: 2025 TTL: 255
MAC Address TTL Forwarded Relay Action
00E0-FC27-6502 63 No None