3com S7906E Guide De Référence

Page de 2327
 
2-16 
vlan-id  value: Specifies the VLAN ID of test frames. The value argument ranges from 1 to 4094 and 
defaults to 1. 
Description 
Use the linktest command to test the connectivity of the optical link between the OLT and the ONU.  
Make sure the ONU is online before you perform the link connectivity test. 
Examples 
# Set the number of test frames to 100 to test the link between the OLT and ONU 3/0/1:1.  
<Sysname> system-view 
[Sysname] interface onu 3/0/1:1 
[Sysname-Onu3/0/1:1] linktest frame-number 100 
 It may affect data transmission, continue?[Y/N]:y 
 Maximum delay(in TQ): 26408 
 Mean delay(in TQ)   : 24777 
 Minimum delay(in TQ): 19922 
 Sent frames         : 100 
 Received frames     : 100 
 Error frames        : 0 
 
 
If The link is disconnected! is displayed, it means that the ONU sent some frames successfully but no 
correct frames are received, namely, the value of the Received frames field is 0. 
 
loopback enable 
Syntax 
loopback enable 
undo loopback enable 
View 
ONU port view  
Default Level 
2: System level 
Parameters 
None 
Description 
Use the loopback enable command to enable MAC loopback for the ONU.  
Use the undo loopback  enable command to cancel loopback.