3com S7906E Guide De Référence

Page de 2327
 
2-20 
  critical       <=CRIT level messages to OLT      (severity=2) 
  debugging      <=DEBUG level messages to OLT     (severity=7) 
  emergencies    <=EMERG Level Switch to OLT       (severity=0) 
  errors         <=ERR level messages to OLT       (severity=3) 
  information    <=INFO level messages to OLT      (severity=6) 
  notifications  <=NOTICE level messages to OLT    (severity=5) 
  warnings       <=WARN level messages to OLT      (severity=4) 
[Sysname-Onu3/0/1:1] onu-event log enable level errors 
# Disable the OLT attached to ONU 3/0/3:1 from reporting log information to the ONU.  
<Sysname> system-view 
[Sysname] interface onu 3/0/3:1 
[Sysname-Onu3/0/3:1] undo onu-event log enable 
Table 2-6 onu-event log enable level command output description 
Field 
Severity level 
Remarks 
emergencies 
Indicating that the system is unavailable. 
alerts 
Errors that need to be corrected immediately.  
critical 
Critical Information.  
errors 3 
Errors. 
warnings 
Warning Information.  
notifications 
Normal information that needs to be noticed.  
information 
Normal prompt information that needs to be recorded.  
debugging 
Debugging information.  
 
onu port-isolate enable 
Syntax 
onu port-isolate enable 
undo onu port-isolate enable 
View 
ONU port view 
Parameters 
None 
Description 
Use the onu port-isolate enable command to isolate all UNI ports of the ONU.  
Use the undo onu port-isolate enable command to disable UNI port isolation.  
By default, UNI port isolation is disabled.  
Examples 
# Isolate all UNI ports attached to the ONU corresponding to ONU 3/0/1:1.