3com S7906E Guide De Référence

Page de 2327
 
3-6 
[Sysname-Olt1/0/1] alarm llid-mismatch threshold 6000 
alarm local-stable enable 
Syntax 
alarm local-stable enable 
undo alarm local-stable enable 
View 
OLT port view, FTTH view 
Default Level 
2: System level 
Parameters 
None
 
Description 
Use the alarm local-stable enable command to enable the local stable alarm. 
Use the undo alarm local-stable enable command to disable the local stable alarm. 
The system generates a local stable alarm in case of an ONU misuse in the system, for example, when 
an OAM 2.0 ONU and an OAM 3.3 ONU are mixed in the same system. (All ONUs in the same system 
must adopt the same OAM version.) 
The local stable alarm differs from the remote stable alarm in the following ways: 
 
The local stable alarm is generated at the OLT side. 
 
The remote stable alarm is generated at the ONU side and will be reported to the OLT. 
By default, this function is enabled. 
Related commands: alarm remote-stable
Examples 
# Enable the local stable alarm OLT 3/0/1.  
<Sysname> system-view 
[Sysname] interface olt 3/0/1 
[Sysname-Olt3/0/1] alarm local-stable enable 
alarm oam critical-event enable 
Syntax 
alarm oam critical-event enable 
undo alarm oam critical-event enable 
View 
OLT port view, FTTH view