3com S7906E Guide De Référence

Page de 2327
 
3-7 
Default Level 
2: System level 
Parameters 
None
 
Description 
Use the alarm oam critical-event enable command to enable the critical event alarm. 
Use the undo alarm oam critical-event enable command to disable the critical event alarm. 
By default, the critical event alarm is enabled.  
There are two types of critical events: local link fault and dying gasp. The system generates a critical 
event alarm when one of the two events occurs. 
Examples 
# Enable the critical event alarm on OLT 3/0/1. 
<Sysname> system-view 
[Sysname] interface olt 3/0/1 
[Sysname-Olt3/0/1] alarm oam critical-event enable  
alarm oam dying-gasp enable 
Syntax 
alarm oam dying-gasp enable 
undo alarm oam dying-gasp enable 
View 
OLT port view, FTTH view 
Default Level 
2: System level 
Parameters 
None
 
Description 
Use the alarm oam dying-gasp enable command to enable the dying gasp alarm. 
Use the undo alarm oam dying-gasp enable command to disable the dying gasp alarm. 
By default, the dying gasp alarm is enabled.  
The system generates a dying gasp alarm when a system error, a data loading error or any other 
nonreversible errors occurs. 
Examples 
# Enable the dying gasp alarm on OLT 3/0/1.  
<Sysname> system-view 
[Sysname] interface olt 3/0/1