3com S7906E Guide De Référence

Page de 2327
 
3-9 
 
 
When the upper limit and the lower limit of the alarm threshold are set to 0, large amount of alarms 
are generated immediately. Since alarm events are carried in the OAM packets, large amount of 
OAM packets are generated. In this case, OAM packets may be lost. 
 
The commands here take effect only for OAM 2.0 and above.  
 
Examples 
# On ONU 1/0/1:1, set the higher window size, lower window size, higher alarm threshold, and lower 
alarm threshold for the error symbol period alarm to 1, 3, 10, and 30 respectively.  
<Sysname> system-view 
[Sysname] interface onu 1/0/1:1 
[Sysname-Onu1/0/1:1] alarm oam error-symbol-period window-high 1 window-low 3 threshold-high 
10 threshold-low 30 
alarm oam error-symbol-period enable 
Syntax 
alarm oam error-symbol-period enable 
undo alarm oam error-symbol-period enable 
View 
OLT port view, ONU port view, FTTH view 
Default Level 
2: System level 
Parameters 
None
 
Description 
Use the alarm oam error-symbol-period enable command to enable the error symbol period alarm. 
Use the undo alarm oam error-symbol-period enable command to disable the error symbol period 
alarm. 
By default, the error symbol period alarm is enabled. 
 
 
The commands here take effect only for OAM 2.0 and above.