3com S7906E Guide De Référence

Page de 2327
 
3-15 
 
The commands here take effect only for OAM 2.0 and above.  
 
Examples 
# Enable the error frame seconds summary alarm for the ONU corresponding to ONU 3/0/1:1.  
<Sysname> system-view 
[Sysname] interface onu 3/0/1:1 
[Sysname-Onu3/0/1:1] alarm oam error-frame-seconds-summary enable 
alarm oam local-link-fault enable 
Syntax 
alarm oam local-link-fault enable 
undo alarm oam local-link-fault enable 
View 
OLT port view, FTTH view 
Default Level 
2: System level 
Parameters 
None
 
Description 
Use the alarm oam local-link-fault enable command to enable the local link fault alarm. 
Use the undo alarm oam local-link-fault enable command to disable the local link fault alarm. 
By default, the local ink fault alarm is enabled.  
The system generates a local link fault alarm when the receiving direction of the local data terminal is in 
trouble. 
Examples 
# Enable the local link fault alarm on OLT 3/0/1.  
<Sysname> system-view 
[Sysname] interface olt 3/0/1 
[Sysname-Olt3/0/1] alarm oam local-link-fault enable 
alarm oam-vendor-specific enable 
Syntax 
alarm oam-vendor-specific enable 
undo alarm oam-vendor-specific enable