3-21 
timer monitor 
Syntax 
timer monitor seconds 
undo timer monitor 
View 
FTTH view 
Default Level 
3: Manage level 
Parameters 
seconds: Alarm monitor period, ranging from 1 to 3600 (in seconds). The system default is 80 seconds. 
Description 
Use the timer monitor command to configure the alarm monitor period of the system.  
Use the undo timer monitor command to restore the default monitor period. 
Examples 
# Configure the alarm monitor period of the EPON system to 100 seconds. 
<Sysname> system-view 
[Sysname] ftth 
[Sysname-ftth] timer monitor 100 
timer sample 
Syntax 
timer sample  seconds 
undo timer sample 
View 
FTTH view  
Default Level 
3: Manage level 
Parameters 
seconds: Sampling interval (in seconds). It is in the range 1 to 3600 and defaults to 4. 
Description 
Use the timer sample command to set the sampling interval for the system.  
Use the undo timer sample command to restore the default sampling interval for the system. 
Examples 
# Set the sampling interval of the EPON system to 10 seconds.