3com S7906E Guide De Référence

Page de 2327
 
1-33 
Parameters 
number: Maximum number of times the device deletes forwarding address entries within a certain 
period of time immediately after it receives the first TC-BPDU, in the range of 1 to 255.  
Description 
Use the stp tc-protection threshold command to configure the maximum number of times the device 
deletes forwarding address entries within 10 seconds immediately after it receives the first TC-BPDU. 
Use the undo stp tc-protection threshold command to restore the system default.  
By default, the device deletes forwarding address entries a maximum of six times within a certain period 
of time immediately after it receives the first TC-BPDU.  
Examples 
# Set the maximum number of times the device deletes forwarding address entries within a certain 
period of time immediately after it receives the first TC-BPDU to 10.  
<Sysname> system-view 
[Sysname] stp tc-protection threshold 10 
stp timer forward-delay 
Syntax 
stp timer forward-delay centi-seconds 
undo stp timer forward-delay 
View 
System view 
Default Level 
2: System level 
Parameters 
centi-seconds: Forward delay in centiseconds, ranging form 400 to 3000 in steps of 100. 
Description 
Use the stp timer forward-delay command to set the forward delay timer of the device.  
Use the undo stp timer forward-delay command to restore the system default.  
By default, the forward delay timer is set to 1,500 centiseconds.  
In order to prevent temporary loops, a port must go through an intermediate state, the learning state, 
before it transitions from the discarding state to the forwarding state, and must wait a certain period of 
time before it transitions from one state to another to keep synchronized with the remote device during 
state transition. The forward delay timer set on the root bridge determines the time interval of state 
transition.  
If the current device is the root bridge, the state transition interval of the device depends on the set 
forward delay value; for a secondary root bridge, its state transition interval is determined by the forward 
delay timer set on the root bridge.  
The settings of the hello time, forward delay and max age timers must meet the following formulae: