3com S7906E Guide D’Installation Rapide

Page de 155
 
1-21 
Table 1-22 Description of LPU status LEDs 
LED 
Description 
RUN 
ON/OFF: The LPU is faulty or out of position. 
Blinking: The LPU is operating normally. 
ALM 
OFF: The LPU is operational or out of position. 
ON: The LPU is faulty. 
 
 
If the RUN LED flashes at a high frequency, the card is in the startup process, but is not yet operational. 
At system startup, the ALM LED will be ON for a while but it does not mean that the card is faulty.  
 
ACTIVE LED 
The ACTIVE LED shows the active/standby status of the LSQ1MPUA0. If the ACTIVE LED is ON, the 
LSQ1MPUA0 is active; if OFF, the LSQ1MPUA0 is standby. 
RESET button 
A reset button is provided on the LSQ1MPUA0 for you to reset the card when necessary. 
Dedicated S7903E-S SRPU-LSQ1CGP24TSC0 
Applicable model 
S7903E-S 
Technical specifications 
Table 1-23 Technical specifications of the LSQ1CGP24TSC0 
Item 
Specifications 
CPU 
MIPS64, 400 MHz 
Boot ROM  
512 KB 
Flash memory 
64 MB 
DDR SDRAM 
512 MB 
Dimensions (H × W × D) 
45 × 377 × 355 mm (1.77 × 14.84 × 13.98 in.) 
Ports 
Twenty-four 1000Base-X-SFP/100Base-FX-SFP ports, 
eight of which can form eight Combo ports with the eight 
10/100/1000Base-T GE ports 
One console port, used for local or remote configuration 
and management of the switch through a dialup 
connection 
One 10/100Base-TX port for management and upgrade 
Power consumption 
25 W to 45 W 
 
Panel and LEDs 
 shows the front panel of the LSQ1CGP24TSC0.