iKey sl-75-oem Guide De Spécification

Page de 2
MOUNTING:     HORIZONTAL  7.85"
            VERTICAL       3.5"
            DEPTH            0.39"

PANEL THICKNESS:  0.06" TO 0.08"
KEY HEIGHT ABOVE PANEL:  0.165"
KEY TRAVEL:  0.055"
POWER: 5 Vdc @ 20 mA, PROVIDED
     BY HOST CPU
TEMPERATURE:  OPERATING FROM 
     0 F TO 140 F (-20 C TO 60 C)
Mounting Instructions:
1.   Turn panel face-down.
2.   Seat keypad into the panel with back facing up.  Seat the
      keypad in the mounting cutout one edge at a time.
3.   Apply silicone adhesive [IKEY recommends SuperFlex by Loctite]
      to back side of silicone overlay (keypad)
       -a small amount should be applied to the the ridges 
         between every other key and on each row.    
       -be sure not to drop silicone on any key contacts
Date:
Sheet:
Drawing Number:
Part Number:   SL-75-OEM
Drawing Title:   MOUNTING CUTOUT
JAE
Revision:   1.0
MKT0043
2 OF 2
2.21.05
Voice:  (512) 837-0283
Fax:  (512) 927-8530
©2005 IKEY,LP
IKEY, LTD
2621 Ridgepoint Dr.  Suite 235
Austin, Texas 78754
.178"
1.914"
3.828"
5.742"
7.655"
.177"
1.218"
2.436"
3.654"
7.300"
3.300"
CUTOUT
5.   Place the PCB (circut board) onto the panel studs , ensuring 
      that no adhesive is misplaced on a key switch.
7.   When the board is in place, allow it to fall onto the keypad.
8.   Spread the keypad to be sure it is well seated on all four sides.
      You may need to look at other side of panel to assure there
      are no gaps in the corners.
9.   Tighten hex nuts until keypad is just SLIGHTLY compressed 
      between panel and PCB.