Gestetner dsc224 Mode D'Emploi
Remote Maintenance by telnet
109
7
Note
❒ To specify the TCP/IP protocol, type ip followed by a space, and then the
IP address.
❒ To specify the IPX/SPX protocol, type ipx followed by a space, and then
the IPX address followed by a decimal, and then the MAC address of the
Network Interface Board.
Network Interface Board.
The following is an example of how to configure registration number 3 with
the IP address 192.168.15.16.
msh> snmp 3 ip 192.168.15.16
The following is an example of how to configure registration number 3 with
the IPX address 7390A448, and the MAC address 00:00:74:62:5C:65.
msh> snmp 3 ipx 7390A448:000074625C65
the IP address 192.168.15.16.
msh> snmp 3 ip 192.168.15.16
The following is an example of how to configure registration number 3 with
the IPX address 7390A448, and the MAC address 00:00:74:62:5C:65.
msh> snmp 3 ipx 7390A448:000074625C65
IPP
Use the ipp command to configure the IPP settings.
❖
❖
❖
❖ Viewing setting
The following command displays the current IPP settings.
msh> ipp
Example output:
Example output:
timeout=900(sec)
auth basic
auth basic
• The “timeout” setting specifies how many seconds the computer keeps try-
ing to access the network printer to send print jobs when no connection can
be made.
be made.
• The “auth” setting indicates the user authorization mode.
❖
❖
❖
❖ IPP timeout configuration
Specify how many seconds to wait before canceling a print job if it has been
interrupted for some reason. The range of time can be changed between 30 to
65535 seconds.
interrupted for some reason. The range of time can be changed between 30 to
65535 seconds.
msh> ipp timeout {30 - 65535}
❖
❖
❖
❖ IPP user authorization configuration
Use the IPP user authorization to restrict users that can print with IPP. The de-
fault is “off” .
fault is “off” .
msh> ipp auth {basic|digest|off}
• “basic” and “digest” are user authorization setting.
• “off” removes the user's authorization.
• “off” removes the user's authorization.
Note
❒ If you select “basic” or “digest”, see next section “Configuring the IPP User
Authorization” for how to configure the user name. Up to ten user names
are available.
are available.