In  this  enterprise  campus  application  example,  FlexPoint 
10/100  media  converters  are  installed  in  a  14-Module 
Redundant Power chassis for high-density fiber distribution 
from  UTP  switch  equipment  at  the  Network  Core.   A  UTP 
workgroup switch (A) is connected via fiber with a standalone 
FlexPoint 10/100 media converter.  Another FlexPoint 10/100 
converts  the  fiber  to  UTP  in  a  fiber-to-desktop  application 
(B).   An  Ethernet  switch  (C)  is  connected  directly  via  fiber 
to the FlexPoint module at the Network Core.  In all cases, 
multimode or single-mode fiber can be used, and fiber links 
can be extended up to 120km using single-mode fiber.
sPeCIFICatIONs
aPPlICatION examPle
OrderINg INFOrmatION
Model Type 
10/100
Protocols 
IEEE 802.3, 10BASE-T, 100BASE-TX, 100BASE-FX
UTP Cable 
EIA/TIA 568A/B, Category 5 and higher
Fiber Cables
Multimode: 50/125, 62.5/125, 100/140µm 
Single-mode: 9/125µm
UTP Connectors 
RJ-45
Fiber Connectors SC, ST, MT-RJ, LC
Switches 
User Selectable UTP Crossover, AN/Man, 
 10/100UTP, UTP FDX/HDX, Fiber FDX/HDX
LED Displays
Power:  Yellow LED = Power Applied
UTP AN:  Green LED = Auto Negotiation Enabled
UTP Duplex:  Green LED 
                On: Set to Full-Duplex 
                Off: Set to Half-Duplex
UTP Link/Receive:  Green LED = Device Present
UTP 10Mbps:  Yellow LED = Data Received 
UTP 100Mbps:  Green LED = Data Present 
Fiber Duplex Mode:  Green LED = Device Present 
                On: Set to Full-Duplex 
                Off: Set to Half-Duplex 
Fiber Link/Receive:  Green LED = Device Present
Dimensions 
W: 3.0" x D: 4.0" x  H: 1.0"
Weight
 6 oz. (without power adapter)
Compliance 
UL, CE, FCC Class A
Power 
Requirements
 
Nominal Voltage: 
Voltage Range: 
Power Nominal: 
Maximum Power:
Barrel Connector 
9VDC 
6.0 to 15.0VDC 
0.5A @ 9VDC 
1A @ 9VDC
Molex Connector 
5VDC 
4.75 to 5.25VDC 
0.8A @ 5VDC 
1A @ 5VDC
Temperature
Standard Operating:   0 to 50 °C 
Wide Operating:  -40° C to 60° C 
Extended Operating:   -40° C to 75° C 
Storage:   40° C to 80° C
Humidity 
5 to 95% (non-condensing)
Altitude 
-100m to 4000m
MTBF (Hours) 
Module without Power Adapter: 1,100,000 
Module with Power Adapter 
-1: 250,000 
Module with Power Adapter 
-2: 100,000
Fiber Type
Distance
Connector Type
Tx / Rx 
Wavelength 
[nm]
Min. Tx 
Power 
[dBm]
Max. Tx 
Power 
[dBm]
Min. Rx 
Sense 
[dBm
Max. Rx 
Power 
[dBm]
Optical 
Power 
Budget
ST
SC
MT-RJ
LC
MM
5km
4342-x
4340-x
4346-x
4355-1x
1310
-24
-14
-31
-14
7
SM
30km
4343-x
4341-x
4348-x
4355-2x
1310
-15
-8
-31
-8
16
SM
60km
4345-x
4344-x
-
4355-3x
1310
-5
0
-31
-3*
26
SM
120km
-
4349-x
-
4355-4x
1550
-5
0
-31
-3*
26
SM/SF
20km
-
4357-1x
-
-
1310/1550
-15
-5
-30
-3
15
SM/SF
20km
-
4357-2x
-
-
1550/1310
-15
-5
-30
-3
15
For wide temperature (-40 to 60º C), add a ""W"" to the end of the model number.  Consult factory for extended temperature (-40 to +75º C) models. 