Lab.gruppen c 10 4x Guide De Spécification

Page de 1
Voltage Peak Limiter Load vs Power Tables
C Series C 20:8X, C 10:8X, C 10:4X, C 5:4X: Dedicated Installation Amplifiers 
C Series amplifiers include the user-definable Voltage Peak Limiter (VPL) function. Rear-panel DIP-switch settings allow the output voltage 
to be adjusted and consequently the output power available. The following tables provide information, for the listed C Series models, about 
resultant output power at typical loads (single-channel and bridged operation) with the available VPL settings.
L a b . g r u p p e n   a b   •   S w e d e n
  i n t e r n a t i o n a L   c o n t a c t   •   i n f o @ L a b g r u p p e n . c o m       |       u S   c o n t a c t   •   i n f o u S @ t c e L e c t r o n i c . c o m
w w w . l a b g r u p p e n . c o m
VPL Setting
V peak
Vrms
16 !
8 !
4 !
2 !
Hi Z 
100 V
100
71
*250
*250
**250
n.r.
250
63 V
63
45
125
250
**250
n.r.
n.a.
45 V
45
32
60
125
250
**125
n.a.
32 V
32
23
30
60
125
**125
n.a.
* = PAL limited to this power when all channels driven
** = Current limited to this power 
n.r. = Not recommended
n.a. = Not applicable
VPL Setting
V peak
Vrms
16 !
8 !
4 !
2 !
Hi Z
100 V
200
141
*500
**500
n.r.
n.r.
500
63 V
126
90
500
**500
n.r.
n.r.
500
45 V
90
64
250
500
**250
n.r.
n.a.
32 V
64
45
125
250
**250
n.r.
n.a.
* = PAL limited to this power when all channels driven
** = Current limited to this power
n.r. = Not recommended
n.a. = Not applicable
Voltage Peak Limiter 
Output power bridged per two channels (W)
Load
C 20:8X / C 10:4X
Voltage Peak Limiter 
Output power per channel (W)
Load
VPL Setting
V peak
Vrms
16 !
8 !
4 !
2 !
Hi Z
100 V
100
71
*125
*125
n.r.
n.r.
125
63 V
63
45
125
*125
**125
n.r.
n.a
45 V
45
32
60
125
**125
**60
n.a
32 V
32
23
30
60
125
**60
n.a
* = PAL limited to this power when all channels driven
** = Current limited to this power
n.r. = Not recommended
n.a.= Not applicable
VPL Setting
V peak
Vrms
16 !
8 !
4 !
2 !
Hi Z
100 V
200
141
*250
**250
n.r.
n.r.
250
63 V
126
90
**250
**250
n.r.
n.r.
250
45 V
90
64
250
**250
**125
n.r.
n.a.
32 V
64
45
125
250
**125
n.r.
n.a.
* = PAL limited to this power when all channels driven
** Current limited to this power
n.r. = Not recommended
n.a.= Not applicable
C 10:8X / C 5:4X
Voltage Peak Limiter 
Output power bridged per two channels (W)
Load
Voltage Peak Limiter 
Output power per channel (W)
Load
Item no. VPL-CSX