Architect’s and Engineer’s Specifications
C Series: Dedicated Installation Amplifiers
C 16:4
Overview: Channel Modes and Network 
The  power  amplifier  shall  provide  four  discrete  channels  of  
amplification. Rear-panel switches shall enable bridging of adjacent 
channels to allow reconfiguration as a 2- or 3-channel amplifier, with 
increased  power  output  available  through  the  bridged  channels. 
Each channel (discrete or bridged) shall be capable of independently  
driving  either  low  impedance  or  high  impedance  (70  Vrms  /100  V 
peak) loads. The amplifier shall employ a proprietary tracking Class 
D output circuit topology. The amplifier shall be equipped with sen-
sing  and  communication  circuits  to  allow  comprehensive  remote 
control and monitoring functions via a separate network bridge. The 
proprietary  control  and  monitoring  network  shall  employ  TCP/IP  
protocols, use Cat-5 cable for interconnection, and allow remote con-
trol from either the network bridge front-panel or from an external PC 
using proprietary software.
Power Output and Performance
Maximum  total  output  of  all  four  channels  shall  be  1600  watts.  In 
discrete  four-channel  mode,  each  amplifier  channel  shall  deliver 
maximum  continuous  output  power  as  follows:  400  watts  into  16 
ohms, 400 watts into 8 ohms; 300 watts into 4 ohms; or 400 watts 
into a high impedance (70 Vrms /100 V peak) load. Maximum out-
put voltage per channel shall be 100 Vrms; maximum output current 
per channel shall be 8.5 Arms. In bridged mode, each bridged chan-
nel shall deliver maximum continuous output power as follows: 800 
watts into 16 ohms; 600 watts into 8 ohms; or 800 watts into a high 
impedance (140 Vrms / 200 V peak) load.
Default  amplifier  gain  shall  be  35  dB,  with  rear-panel  adjustment 
from 23 - 44 dB in 3 dB increments, selectable for each channel. For 
bridged  channels,  the  amplifier  shall  automatically  compensate  –6 
dB  gain  internally  to  maintain  operation  of  all  channels  at  selected 
gain.
The  amplifier  shall  exhibit  the  following  performance  parameters 
with  gain  set  at  35  dB  and  VPL  (Voltage  Peak  Limiter)  at  141  V:  
Frequency response shall be 6.8 Hz to 34 kHz, +0/-3dB at 1 watt into 
an 8 ohm load; channel separation shall be greater than 70 dB; and 
signal-to-noise ratio shall be 112 dBA. THD at 1 watt, 20 Hz – 20 kHz, 
shall be less than 0.1%; THD at 1 kHz shall be no more than 0.05% 
at 1 dB below clipping.
A voltage peak limiter shall limit peak output as determined by rear-
panel switches. In discrete four channel mode, peak voltage shall be 
selectable in eights steps across a range of 141 V to 42 V. In bridged 
mode, peak voltage shall be selectable in eight steps from 282 V to 
84 V. The voltage limiter mode shall be selectable for either hard or 
soft limiting characteristics.
Connectors, Controls, and Indicators
The  following  connectors  and  controls  shall  be  provided  on  the 
REAR-PANEL  of  the  amplifier.  The  four  input  connectors  shall  be 
 
electronically  balanced,  3-pin  Phoenix  connectors.  The  four  output  
connectors shall be 2-pole barrier strip screw connectors. A group 
of seven DIP-switches shall determine the following: Amplifier gain 
(23  dB  to  44  dB  in  3  dB  increments);  option  active;  fan  masked; 
and  bridged  mode  selection  for  channel  pairs.  A  group  of  sixteen 
DIP-switches shall determine Voltage Peak Limiter values for each  
channel,  selectable  in  eight  steps,  and  Hard  or  Soft  limiting  
characteristic. Two RJ45 connectors shall be provided for input and  
output of the control/monitoring network signals. An LED adjacent 
to the RJ45 connectors shall indicate active or inactive status of the  
network.
The  following  indicators  and  controls  shall  be  provided  on  the 
FRONT-PANEL  of  the  amplifier.  Four  level  control  potentiometers, 
one for each channel, shall be provided beneath a front-panel secu-
rity cover; potentiometers shall be detented and provide attenuation 
from 0 dB to minus infinity in 21 steps. Individual switches shall be 
provided for power on/off and remote power on/off enabling. Front-
panel LED indicators shall be provided to show status of power on/
off (green), network connection (blue), Power Average Limiter (red), 
and  option  card  active  (yellow).  Additional  LED  indicators  shall  be 
provided to show the status of the following for each channel: sig-
nal present and high-impedance warning (green/red), signal present 
at –10 dB and –4 dB (2 x green), voltage peak limiter clipping (red),  
current peak limiter (CPL) active (orange), very high frequency (VHF)  
warning  (yellow),  high  temperature  warning  (yellow  flashing),  and 
high  temperature  fault  with  output  muted  (yellow  constant).  Mute 
shall be indicated by illumination of both the temperature and VHF 
LEDs on a channel; fault shall be indicated by illumination of both the 
CPL and VHF LEDs on a channel. 
Power Supply, Protection, and Cooling 
The  power  supply  shall  be  a  regulated  switch  mode  type.  The  
amplifier shall operate from AC line sources of either 230 V nominal 
or 115 V nominal, with operating ranges of 130 – 265 V and 65 – 135 
V  at  line  frequencies  of  50  Hz  or  60  Hz.  Minimum  power-up  volt-
ages  are  171  V  (230  V  nominal)  and  85  V  (115  V  nominal).  A  soft 
start circuit shall limit current inrush at power-up to 5 A. The amplifier 
shall  be  equipped  with  a  PAL™  (Power  Average  Limiter)  circuit  to 
prevent excessive current draw. The amplifier shall be cooled by two  
temperature-controlled,  variable-speed  fans,  with  air  flow  from  
front-  to-back.  Adaptive  fan  on/off  function  shall  be  dependent  on 
presence of an output signal.
Physical
The amplifier shall be 483 mm (19 in.) wide, 88 mm (3.5 in. / 2 U) 
high, and 343 mm (13.5 in.) deep. The weight shall be 12 kg (26.4 
lbs). The cabinet shall be black painted steel with a grey painted steel 
front-panel. 
The amplifier shall be approved for use as specified by CE, ANSI/UL, 
ETL and the FCC. The amplifier shall be the Lab.gruppen C 16:4.
Item no. AES-C164_V4
L a b . g r u p p e n   a b   •   S w e d e n
  i n t e r n a t i o n a L   c o n t a c t   •   i n f o @ L a b g r u p p e n . c o m       |       u S   c o n t a c t   •   i n f o u S @ t c e L e c t r o n i c . c o m
w w w . l a b g r u p p e n . c o m