Lab.gruppen fp 10000q Mode D'Emploi

Page de 31
12  FP+ Series Operation Manual 
6  QUICK GUIDE OVERVIEW
6.2.1  Network and Configuration section
Four-channel model shown. Two-channel versions 
have VPL and Bridge Mode switches for channels 
A and B only. All models have different VPL values. 
Functions are otherwise identical.
44dB 
41dB 
38dB 
35dB 
32dB 
29dB 
26dB 
23dB 
150V 
121V 
101V 
83V 
70V 
56V 
47V 
38V 
6.2.2  The dIP-switch features
The following features may be adjusted using the 
DIP-switches on the rear panel of the amplifier. 
Gain - Globally set for all channels, from +23 dB to +44 
dB in 3 dB steps.
Option active - Not currently implemented.
fan  Masked  -  When  on,  engages  the  intelligent 
fan feature; fan speed is lowered when no signal is  
present. 
Bridge  A+B  and  C+d-  Switches  the  channel  pairs 
into bridge mode operation An automatic -6 dB gain 
compensation is applied.
VPL - The Voltage Peak Limiter provides optimum 
peak voltage settings for each channel. Eight discrete 
levels are selectable except on the FP 6000Q, which 
has six levels.
 
VPL 
fP 6000q
fP 7000
fP 10000q
fP 13000
101 V
155 V
150 V
195 V
83 V
121 V
121 V
170 V
70 V
101 V
101 V
140 V
56 V
83 V
83 V
116 V
47 V
70 V
70 V
100 V
38 V
56 V
56 V
80 V
47 V
47 V
66 V
38 V
38 V
54 V
VPL in Bridge Mode
fP 6000q
fP 7000
fP 10000q
fP 13000
202 V
310 V
300 V
390 V
166 V
242 V
242 V
340 V
140 V
202 V
202 V
280 V
112 V
166 V
166 V
232 V
94 V
140 V
140 V
200 V
76 V
112 V
112 V
160 V
94 V
94 V
132 V
76 V
76 V
108 V
Mode - Select VPL mode to either Hard or Soft 
operation. For channels driving sub-woofers and 
low-frequency drivers, it is recommended to use 
the Hard setting for optimal operation. For mid- and 
high- frequency drivers, always select Soft.