Overall amplifier input gain is adjusted using the 
input stage DIP-switches. Please note that the gain 
setting is global, affecting all channels. Following 
the input stage, the dedicated level control on each 
channel allows signal attenuation from 0 dB to minus 
infinity. 
The Current Peak Limiter (CPL) section dynamically 
limits the input signal based on three parameters: 
sensed current level, feedback from the output stage, 
and sensed voltage clip from the VPL (and output  
amplifier voltage clip if “Soft Clip” is activated). This 
ensures that power output is maintained within the 
design limits of the amplifier.
The adjustable Voltage Peak Limiter (VPL) sets the  
maximum  output  voltage  and  therefore  also  the 
maximum  output  power.  Eight  different  voltage 
stages are available using the DIP-switches on the 
rear panel of all models, except the FP 6000Q which 
provides six voltage stages. 
The sophisticated output section monitors faults 
and  generates  appropriate  warnings,  which  are  
displayed on the amplifier front panel and transmitted 
through the NomadLink network. These alerts allow 
the operator to adjust system settings and thereby 
avoid problems. In the rare event that conditions are 
extraordinarily severe, the amplifier will shut down 
until the fault or problem setting has been rectified 
or adjusted. These sensing circuits are also employed 
to feed back voltage and current level information, 
via  a  side  chain,  to  the  limiters.  Sensing  circuits 
also transmit local amplifier module temperature 
and power supply temperature to the appropriate 
protection mechanisms. Read the Protection, Faults 
and Warnings section for further details.
7.1  Introduction
The  following  sections  provide  comprehensive  
information on amplifier connection, setup, operation, 
and performance. The detailed information included 
here is essential to realizing the full functionality of the  
FP+ Series amplifiers.
7.2  Operation precautions
Make sure that the Power switch and the Remote 
switch on the amplifier front panel are set to 
“off” before making any input, output or network 
connections, and also before manipulating the 
DIP-switches on the rear panel.
Make sure that the AC mains voltage is correct 
and matches the voltage printed on the rear panel 
of the amplifier (115 V or 230 V). 
Make sure that no signal is present at the input 
to the amplifier when powering up. An input 
signal could produce an unintentionally loud initial 
volume from the speakers.
7.3  Signal flow and headroom
7.3.1  Signal flow blocks
All FP+ amplifiers have the same signal flow, and 
the same feature sets.  The only internal differences 
are in the maximum output current per channel and 
VPL settings.
The input stage of all FP+ Series amplifiers has a 
high sensitivity to provide ample system headroom. 
This in effect means that the input stage is almost 
impossible to clip.
OPERATION AND PERFORMANCE  7