Lab.gruppen fp 10000q Mode D'Emploi

Page de 31
18  FP+ Series Operation Manual 
Two-channel amplifiers – Two-channel amplifiers 
are wired in the following manner. The right Speakon 
connector, Channel A+B, provides outputs for both 
Channel A and Channel B.  This output is useful when 
wiring the amplifier for bridged mono operation. See 
section 7.4.6. The left Speakon connector provides 
an output for Channel B only.
Connect the + and – loudspeaker cables as shown 
in the illustrations below.
Channel A and B into two
separate Speakons
Channel A and B into one
Speakon (Stereo and Bi-amp)
Bridge mono
four-channel amplifiers – Additional connectors 
are provided for Channel C and Channel D. Channel 
C functions as Channel A above, and Channel D as 
Channel B above.
7.4.4  Binding Post (BP) Output connectors
Refer to the instructions in this section if your amplifier 
is equipped with Binding Post output connectors.
Binding Post outputs - two-channel models
Binding Post outputs - four-channel models
Connect the positive (+) loudspeaker cable to the 
positive (+) red terminals.  Connect the negative (-) 
loudspeaker cable to the negative (-) black terminals. 
For bridge mode, connect the positive (+) terminal 
on Channel A to the positive (+) loudspeaker cable 
and the negative (-) terminal on Channel B to the 
negative (-) loudspeaker cable. 
Channels  C  and  D  on  four-channel  versions  are 
connected in the same manner. For bridge mode, 
connect the positive (+) terminal on Channel C to the 
positive (+) loudspeaker cable and the negative (-) 
terminal on Channel D to the negative (-) loudspeaker 
cable. 
The  outputs  on  all  FP+  Series  amplifiers 
produce  high  voltage.  Do  not  connect  or 
disconnect the loudspeaker cables while the mains 
power is on. Never operate the amplifier with any 
portion of bare loudspeaker wire exposed. Also, 
attach  the  safety  cover  (4-channel  Speakon  
versions  only)  on  the  speaker  terminals  for  safe 
operation  and  to  comply  with  electrical  product  
approvals.
7  OPERATION AND PERFORMANCE