Lab.gruppen fp 10000q Mode D'Emploi

Page de 31
   
 FP+ Series Operation Manual  
21
7.5  Protection, faults and  
warnings
7.5.1  Introduction
The FP+ Series amplifiers incorporate a sophisticated 
and comprehensive set of protection features. Faults 
and warnings are indicated on the front panel and 
reported via the NomadLink network for indication 
on the DeviceControl GUI. 
7.5.2  Safe Operating Area detector (SOAd)
The Safe Operating Area Detector (SOAD) compares 
output voltage against output current to ensure that 
the output transistors are working inside their safe 
operating area.
The SOAD provides fault monitoring and input to 
the Current Peak Limiter (CPL). The SOAD has no 
dedicated indicator, and its operation is revealed only 
in conjunction with features such as the CPL.
7.5.3  Very high frequency (Vhf) protection
All FP+ Series amplifiers include protection circuits 
that detect continuous Very High Frequency content 
in  the  input  signal.  The  detection  begins  at  ap-
proximately 10 kHz and moves upwards to include 
ultrasonic signals If VHF signals are detected, the 
output will mute for 6 seconds before re-measuring. 
Once no continuing VHF signal is detected, the output 
un-mutes and returns to normal operation. 
 
This feature recognizes that continuous full-scale VHF 
signals do not appear in “natural” sources such as 
music. Any such signals can therefore be considered 
as a fault when present. VHF protection is essential 
in avoiding damage to high frequency drivers.
The VHF protection operational area is dependent 
on output power level and frequency. The illustration 
below shows a decreasing threshold on the output 
power level, starting at approximately 10 kHz and 
rising with a -6 dB slope. This defines the VHF protec-
tion area. When continuous output power above 
the threshold line is detected the VHF protection 
becomes active.
20 Hz
10 kHz
20 kHz
30 kHz
- 6 dB slope
VHF protection
operation area
Max. Peak 
output power
Max. Continous 
output power
Output
power
Attack time 
VHF protection
Slow
Fast
20 Hz
10 kHz
20 kHz
30 kHz
The Attack time for the VHF protection is increa-
singly shorter at higher frequencies. For example, an 
ultrasonic continuous signal will cause the outputs to 
mute rapidly, where it will take several milliseconds 
for a 10 kHz continuous signal to trigger the output 
mute. This is shown in the illustration above.
The VHF protection is NOT a limiter and does not 
alter the amplifier’s frequency response. It is imple-
mented solely to detect continuous VHF content. The  
amplifier will always pass VHF peaks at full power, 
with no effect on musical “transients”.
The VHF protection is indicated by a yellow LED on 
the amplifier front panel, with output muting for 6 
seconds when in action. It is reported as a fault via the 
NomadLink network on the DeviceControl GUI.
If  you  bench  test  the  amplifier  using  a 
continuous, full scale sine-wave input above 
10 kHz, the VHF protection will activate and 
prevent measurement of full peak output 
power. (Output will be muted long before maximum 
output power is attained.)  To measure the true peak 
output power, use a burst signal.
7.5.4  dC protection
DC  protection  is  implemented  on  each  output 
to  prevent  damage  to  connected  loudspeakers. 
DC present at the output will trigger muting and  
illuminate the fault LED indicator. Any DC present 
at the output indicates a hardware malfunction that 
requires servicing of the amplifier. 