 FP+ Series Operation Manual  
25
Up to 60 amplifiers can be connected to one NLB 
60E in a daisy-chain or closed loop.
When the NLB 60E is powered up, the NomadLink 
network receives phantom power. This causes the 
blue NomadLink LED on the amplifier front panel 
and the NomadLink LED on the rear panel to light 
up. NomadLink is active even when the amplifier has 
mains power disconnected or is not yet powered 
up. 
The  amplifier  does  not  have  a  stand-by  power  
supply  for  the  network.  The  network  is  solely  
powered from the NLB 60E. Should an amplifier fail 
or be inadvertently disconnected from the mains, 
network integrity is fully maintained and all amplifiers 
remain visible on the system.
7.7.2  Connection and setup
The NomadLink network requires use of an NLB 
60E NomadLink Bridge & Network Controller. The 
NomadLink network is established by connecting the 
NLB 60E OUT port to the first amplifier’s IN port. 
Then a daisy-chain is established by connecting the 
first amplifier’s OUT port to the next amplifier’s IN 
port, and so on. If a closed loop network is desired 
for improved redundancy (highly recommended), the 
last amplifier’s OUT port must be connected to the 
NLB 60E’s IN port.
For all connections, straight Cat-5 RJ45-equipped 
Ethernet cables should be used.
OPERATION AND PERFORMANCE  7
Optimal NomadLink performance can only 
be  assured  when  using  Cat-5  cables.  
However, as NomadLink is only using two 
wires  +  ground  for  communication  and 
phantom power it is possible to create converters 
from RJ45 to, for example, XLR connectors using 
2-wire shielded cable. The NomadLink network can 
then  be  operated  using  a  standard  tie-line  in  a  
multicore signal distribution system. See the drawing 
below  for  an  example  of  how  to  create  a   
converter.
If any cable format or connection other than 
Cat-5  (or  better)  and  RJ45  is  utilized,  
network  performance  may  be  compro-
mised. In this event Lab.gruppen cannot 
guarantee that the NomadLink network will be fully 
operational.
7.7.3  NomadLink network cable lengths
In situations where the amplifiers and the NLB 60E 
will  be  positioned  in  different  locations  at  some  
distance  from  each  other,  or  where  groups  of  
amplifiers within a single subnet with up to 60 units 
will be installed with a distance in between, these 
general rules may be considered: