Architects’ and Engineers’ Specification
FP+ Series: Dedicated Touring Amplifiers
FP 10000Q
Item no. AES-FP10000Q_V2
L a b . g r u p p e n   a b   •   S w e d e n
  i n t e r n a t i o n a L   c o n t a c t   •   i n f o @ L a b g r u p p e n . c o m       |       u S   c o n t a c t   •   i n f o u S @ t c e L e c t r o n i c . c o m
w w w . l a b g r u p p e n . c o m
Overview: Channel Modes and Network 
The power amplifier shall provide four discrete channels of amplifica-
tion. Rear-panel switches shall enable bridging of adjacent channels 
to allow reconfiguration as a 2- or 3-channel amplifier, with increased 
power output available through the bridged channels. The amplifier 
shall employ a proprietary tracking Class D output circuit topology. 
The  amplifier  shall  be  equipped  with  sensing  and  communication 
circuits to allow comprehensive remote control and monitoring func-
tions  via  a  separate  network  bridge.  The  proprietary  control  and 
monitoring  network  shall  use  Cat-5  cable  for  interconnection,  and 
shall allow control and monitoring directly from the network bridge’s 
front-panel or, via the bridge, from an external PC running proprietary 
software.
Power Output and Performance
Maximum total output of all four channels shall be 10000 watts. In 
discrete four-channel mode, each amplifier channel shall deliver max-
imum continuous output power as follows: 660 watts into 16 ohms, 
1300 watts into 8 ohms; 3100 watts into 4 ohms; or 2500 watts into 
2  ohms.  Maximum  output  voltage  per  channel  shall  be  150  Vrms; 
maximum output current per channel shall be 38 Arms. In bridged 
mode, each bridged channel shall deliver maximum continuous out-
put power as follows: 2600 watts into 16 ohms; 4200 watts into 8 
ohms; or 5000 watts into 4 ohms.
Default  amplifier  gain  shall  be  35  dB,  with  rear-panel  adjustment 
from 23 to 44 dB in 3 dB increments, selectable for each channel. For 
bridged channels, the amplifier shall automatically compensate -6 dB 
gain internally to maintain operation of all channels at selected gain.
The  amplifier  shall  exhibit  the  following  performance  parameters 
with  gain  set  at  35  dB  and  VPL  (Voltage  Peak  Limiter)  at  150  V:  
Frequency response shall be 6.8 Hz to 34 kHz, +0/-3 dB at 1 watt 
into an 8 ohm load; channel separation shall be greater than 70 dB; 
and  signal-to-noise  ratio  shall  be  greater  than  112  dBA.  THD  at  1 
watt, 20 Hz – 20 kHz, shall be less than 0.1%; THD at 1 kHz shall be 
no more than 0.05% at 1 dB below clipping.
A VPL shall limit peak output as determined by rear-panel switches. 
In  discrete  four  channel  mode,  peak  voltage  shall  be  selectable  in 
eights steps across a range of 150 V to 38 V. In bridged mode, peak 
voltage shall be selectable in eight steps from 300 V to 76 V. The 
voltage limiter mode shall be selectable for either Hard or Soft limit-
ing characteristics.
Connectors, Controls, and Indicators
The following connectors and controls shall be on the REAR-PANEL 
of the amplifier. The four input connectors shall be electronically ba- 
lanced  XLR-F.  The  four  output  connectors  shall  be  either  bind-
ing  post  or  Neutrik  Speakon.  A  group  of  seven  DIP-switches  shall  
determine the following: amplifier gain (23 dB to 44 dB in 3 dB incre-
ments); option active; fan masked; and bridged mode selection for 
channel pairs. A group of sixteen DIP-switches shall determine VPL 
values for each channel (selectable in eight steps), and Hard or Soft 
limiting characteristic. Two Ethercon-housed RJ45 connectors shall 
be provided for input and output of the control/monitoring network 
signals. An LED adjacent to the RJ45 connectors shall indicate active 
or inactive status of the network.
The following indicators and controls shall be on the FRoNT-PANEL 
of the amplifier. Four level control potentiometers shall be detented 
and provide attenuation from 0 dB to infinity in 21 steps. Individual 
switches shall be provided for power on/off and remote power on/off 
enabling. Front-panel LED indicators shall be provided to show status 
of power on/off (green), network connection (blue), and PAL (Power 
Average  Limiter)  (red).  Additional  LED  indicators  shall  be  provided 
to show the status of the following for each channel: signal present 
and high-impedance warning (green/red), signal present from -20 dB 
to -4 dB (4x green), VPL clipping (red), CPL (Current Peak Limiter) 
active (orange), VHF (Very High Frequency) warning (yellow), high 
temperature  warning  (yellow  flashing),  and  high  temperature  fault 
with output muted (yellow constant), and Mute (red). 
Power Supply, Protection, and Cooling 
The power supply shall be a regulated switch mode type. The ampli-
fier shall operate from AC line sources of either 230 V nominal or 115 
V nominal, with operating ranges of 130 – 265 V and 65 – 135 V at 
line frequencies of 50 Hz or 60 Hz. Minimum power-up voltages are 
171 V (230 V nominal) and 85 V (115 V nominal). A soft start circuit 
shall limit current inrush at power-up to 5 A. The amplifier shall be 
equipped with a PAL circuit to prevent excessive current draw. The 
amplifier  shall  be  cooled  by  two  temperature-controlled,  variable-
speed fans, with air flow from front-to-back. An adaptive fan on/off 
function shall be dependent on presence of an output signal. 
Physical 
The amplifier shall be 483 mm (19 in.) wide, 88 mm (3.5 in / 2 U) 
high, and 396 mm (15.6 in.) deep. The weight shall be 12 kg (26.4 
lbs).  The  cabinet  shall  be  black  painted  steel  with  a  black  painted 
steel and aluminum front-panel. 
The  amplifier  shall  be  approved  for  use  as  specified  by  CE,  
ANSI/UL, ETL and the FCC. The amplifier shall be the Lab.gruppen 
FP 10000Q.