Lab.gruppen fp 10000q Guide De Spécification

Page de 1
Item no. CDTD_FP7000_V4
L a b . g r u p p e n   a b   •   S w e d e n
  i n t e r n a t i o n a L   c o n t a c t   •   i n f o @ L a b g r u p p e n . c o m       |       u S   c o n t a c t   •   i n f o @ t c u S . c o m
w w w . l a b g r u p p e n . c o m
-10dB
-inf
0
-10dB
-inf
0
B
channel
channel
A
FP SERIES
VHF
TEM
VHF
TEM
channel A
  -20   -15   -10 -4 VPL CPL
channel B
  -20   -15   -10 -4 VPL CPL
BRIDGE A+B
SIG
SIG
PWR
PAL
NOMAD
    LINK
MUTE
MUTE
 
CLIP
 
CLIP
 
HI-IMP
 
HI-IMP
FP7000
R
POW
POW
The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation 
(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
Current Draw and Thermal Dissipation
FP+ Series: Dedicated Touring Amplifiers
FP 7000
FP 7000
Level
Load
Rated Power
Line Current *2)
Watt *1)
Thermal Dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby, with remote power off via NomadLink
0
0
0
0
0
Powered on, idling
92
0
92
316
80
Amp (I)
Watt
Pink noise (1/8 
rated power)
16 
Ω / Ch.
730 x 2
6.8
3.4
411
183
229
781
197
32 
Ω / Bridged
1460 x 1
Ω / Ch.
1450 x 2
10.8
5.4
692
363
329
1123
283
16 
Ω / Bridged
2900 x 1
Ω / Ch.
2800 x 2
17.4
8.7
1176
700
476
1625
409
Ω / Bridged
5600 x 1
Ω / Ch.
3500 x 2
22.0
11.0
1518
875
643
2195
553
Ω / Bridged
7000 x 1
Pink noise (1/4 
rated power) 
*3)
16 
Ω / Ch.
730 x 2
19.6
9.8
800
487
313
1070
270
32 
Ω / Bridged
1460 x 1
Ω / Ch.
1450 x 2
33.3
16.6
1455
967
489
1667
420
16 
Ω / Bridged
2900 x 1
Ω / Ch.
2800 x 2
39.4
19.7
2705
1867
838
2860
721
Ω / Bridged
5600 x 1
Ω / Ch.
3500 x 2
39.4
19.7
3088
2333
754
2574
649
Ω / Bridged
7000 x 1
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Nema L5-30P Twist lock
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and 
specified here is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated 
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be 
tripped even if operation is in excess of max. ratings.