Lab.gruppen fp 10000q Manuel Complémentaire

Page de 1
FP 7000
Architects’ and Engineers’ Specification
FP+ Series: Dedicated Touring Amplifiers
Item no. AES-FP7000_V2
L a b . g r u p p e n   a b   •   S w e d e n
  i n t e r n a t i o n a L   c o n t a c t   •   i n f o @ L a b g r u p p e n . c o m       |       u S   c o n t a c t   •   i n f o u S @ t c e L e c t r o n i c . c o m
w w w . l a b g r u p p e n . c o m
Overview: Channel Modes and Network 
The  power  amplifier  shall  provide  two  channels  of  amplification.  
A  rear-panel  switch  shall  bridge  the  two  channels  for  increased 
power output through a single channel. The amplifier shall employ 
a proprietary tracking Class D output circuit topology. The amplifier 
shall be equipped with sensing and communication circuits to allow 
comprehensive remote control and monitoring functions via a sepa-
rate network bridge. The proprietary control and monitoring network 
shall use Cat-5 cable for interconnection, and shall allow control and 
monitoring directly from the network bridge’s front-panel or, via the 
bridge, from an external PC running proprietary software.
Power Output and Performance
Maximum total output of both channels shall be 7000 watts. Each 
amplifier channel separately shall deliver maximum continuous out-
put  power  as  follows:  730  watts  into  16  ohms,  1450  watts  into  8 
ohms; 2800 watts into 4 ohms; or 3500 watts into 2 ohms. Maxi-
mum output voltage per channel shall be 155 Vrms; maximum out-
put current per channel shall be 42 Arms. In bridged mode, the am-
plifier  shall  deliver  maximum  continuous  output  power  as  follows: 
2900 watts into 16 ohms; 5600 watts into 8 ohms; or 7000 watts 
into 4 ohms.
Default  amplifier  gain  shall  be  35  dB,  with  rear-panel  adjustment 
from 23 to 44 dB in 3 dB increments, selectable for each channel. 
For bridged channels, the amplifier shall automatically compensate - 
6 dB gain internally to maintain operation of all channels at selected 
gain.
The  amplifier  shall  exhibit  the  following  performance  parameters 
with  gain  set  at  35  dB  and  VPL  (Voltage  Peak  Limiter)  at  155  V:  
Frequency response shall be 6.8 Hz to 34 kHz, +0/-3 dB at 1 watt 
into an 8 ohm load; channel separation shall be greater than 70 dB; 
and  signal-to-noise  ratio  shall  be  greater  than  112  dBA.  THD  at  1 
watt, 20 Hz – 20 kHz, shall be less than 0.1%; THD at 1 kHz shall be 
no more than 0.05% at 1 dB below clipping.
A VPL shall limit peak output as determined by rear-panel switches. 
In  discrete  two  channel  mode,  peak  voltage  shall  be  selectable  in 
eights steps across a range of 155 V to 38 V. In bridged mode, peak 
voltage shall be selectable in eight steps from 310 V to 76 V. The 
voltage limiter mode shall be selectable for either hard or soft limit-
ing characteristics.
Connectors, Controls, and Indicators
The following connectors and controls shall be on the REAR-PAnEL 
of  the  amplifier.  The  two  signal  inputs  shall  be  electronically  ba-
lanced  on  XLR-F  connectors,  and  each  input  shall  have  a  parallel 
LInK output on an XLR-M connector. The Speaker Output connec-
tors shall be binding posts or neutrik Speakon. Seven DIP-switches 
shall  be  provided  to  select  the  following:  amplifier  gain  (23  dB  to 
44 dB in 3 dB increments); option active; fan masked; and bridged 
mode selection. Eight additional DIP-switches shall determine VPL 
values for each channel (selectable in eight steps), and Hard or Soft 
limiting characteristic. Two Ethercon-housed RJ45 connectors shall 
be provided for input and output of the control/monitoring network 
signals. An LED adjacent to the RJ45 connectors shall indicate active 
or inactive status of the network.
The following indicators and controls shall be on the FROnT-PAnEL 
of the amplifier. Two level control potentiometers shall be detented 
and provide attenuation from 0 dB to infinity in 21 steps. Individual 
switches shall be provided for power on/off and remote power on/off 
enabling. Front-panel LED indicators shall be provided to show status 
of power on/off (green), network connection (blue), and PAL (Power 
Average  Limiter)  (red).  Additional  LED  indicators  shall  be  provided 
to show the status of the following for each channel: signal present 
and high-impedance warning (green/red), signal present from -20 dB 
to -4 dB (4x green), VPL clipping (red), CPL (Current Peak Limiter) 
active (orange), VHF (Very High Frequency) warning (yellow), high 
temperature  warning  (yellow  flashing),  and  high  temperature  fault 
with output muted (yellow constant), and Mute (red). 
Power Supply, Protection, and Cooling 
The power supply shall be a regulated switch mode type. The ampli-
fier  shall  operate  from  AC  line  sources  of  either  230  V  nominal  or 
115 V nominal, with operating ranges of 130 – 265 V and 65 – 135 V 
at line frequencies of 50 Hz or 60 Hz. Minimum power-up voltages 
are  171  V  (230  V  nominal)  and  85  V  (115  V  nominal).  A  soft  start  
circuit  shall  limit  current  inrush  at  power-up  to  5  A.  The  amplifier 
shall  be  equipped  with  a  PAL  circuit  to  prevent  excessive  current 
draw. The amplifier shall be cooled by two temperature-controlled, 
variable-speed  fans,  with  air  flow  from  front-to-back.  Adaptive  fan 
on/off function shall be dependent on presence of an output signal. 
Physical 
The amplifier shall be 483 mm (19 in.) wide, 88 mm (3.5 in / 2 U) 
high, and 396 mm (15.6 in.) deep. The weight shall be 12 kg (26.4 
lbs).  The  cabinet  shall  be  black  painted  steel  with  a  black  painted 
steel and aluminum front-panel. 
The amplifier shall be approved for use as specified by CE, AnSI/UL, 
ETL and the FCC. The amplifier shall be the Lab.gruppen FP 7000.