NOTE - If the tank heater remains unable to heat, remove 
and inspect heater for cracks in the sheath.
Removal and Replacement:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the water supply tube on the tank lid.
3.  Disconnect  the  black    wires  on  the  limit 
thermstat.
4.  Disconnect the black wire and the white or red wire 
from the tank heater terminals.
5.  Disconnect the pink wire from the liquid level probe 
and the green wire from the tank.
6.  Remove  the  thermostat  capillary  bulb  by  firmly 
pulling-up on the capillary at the tank lid. This will 
disengage the grommet from the tank lid.
7.   Remove the ten #8-32 nuts securing the tank lid to 
the tank.
8.  Remove tank lid with limit thermostat, liquid level 
probe and tank heater as an assembly.
9.  Remove the two hex nuts securing the tank heater 
to the tank lid. Remove tank heater with gaskets 
and discard.
10. Install new tank heater with gaskets on the tank lid 
and secure with two hex nuts.
11. Install  tank  lid  with  limit  thermostat,  liquid  level 
probe and tank heater on the tank and secure with 
ten #8-32 hex nuts.
12. Connect water inlet line to the tank lid.
13. Reconnect the black wires to limit thermostat,  the 
pink wire to the liquid level probe and the green 
wire to the tank. Refer to the limit thermostat and 
the liquid level board and probe sections in this 
manual when reconnecting wires.
14. Refer to Fig. 41  when reconnecting the wires to 
the tank heater.
TANk HEATER - FMD-1 (shown) & FMD-2 (cont.)
SERVICE (cont.)
FIG. 41 TANK HEATER TERMINALS
P1218
WHI or RED to
Main Harness
BLK to Limit
Thermostat
J1
FIG. 42 TANK HEATER SWITCH
TANk HEATER SWITCH - FMD-1 (shown) & FMD-2
P1665
Location:
 
The tank heater switch located inside the dis-
penser on the upper right of the front panel.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the black wires  from the main wiring 
harness.
3.  With the switch in the “ON” lower position check 
for  continuity  between  the  center  and  the  upper 
terminal. With the switch in the “OFF” upper posi-
tion no continuity should be present between center 
and upper terminals.
If continuity is present as described, the tank heater 
“ON/OFF” switch is operating properly.
If continuity is not present as described, replace the 
switch.
Removal and Replacement:
1.  Remove the switch mounting nut on the front of 
the front panel.
2.   Remove switch with wires attached from the rear 
of the front panel.
3.  Remove the wires from the switch terminals and 
discard switch.
4.   Connect the wires to the new switch, refer to Fig. 
43.
5.  Push new switch through hole in the front panel 
and secure with facenut.
29112 101598