10.7.2. Control input function setting items
Unless otherwise specified, use the Parameter setting knob for each parameter selection.
(E1) Control input function setting
C - I N 0 1 –
N O N E
Sets the functions to be assigned to the control input terminals or control buttons of the ZM-9001 or ZM-9002.
[When the function is set to LOADBANK]
(E2)
(When the control input function is set to LOADBANK)
C - I N 0 1 –
L O A D B A N K
Closing the control input terminal recalls the settings saved in a Scene memory bank number.
Assigning a function to the control input terminal or ZM-9001/9002's control button overwrites the previously
set function on it if there is.
(E3) Scene memory bank number selection
C - I N 0 1 – L O A D B A N K
0 1
Select the bank number to recall.
01 – 32 (default: 01)
Setting Range
C-IN01 to 12:
NONE (default), LOADBANK (Scene memory recall), VOLUP (volume
up), VOLDOWN (volume down), CH ON (channel ON), CH MUTE
(channel mute), EMG-MUTE (Cut-off by Emergency control), POWER
(Power ON/OFF remote control)
ZM-IN01 to 12: NONE (default), LOADBANK, VOLUP, VOLDOWN
Setting Range
[When the function is set to VOLUP or VOLDOWN]
C - I N 0 1 –
V O L U P
C - I N 0 1 –
V O L D O W N
(E4)
(When the control input function is set to VOLUP)
(E5)
(When the control input function is set to VOLDOWN)
Assign the volume-up or volume-down function to the control input. 
Closing the control input terminal increases or decreases the volume of the set input or output channel.
Assigning a function to the control input terminal or ZM-9001/9002's control button overwrites the previously
set function on it if there is.