Avaya P550 Manuel D’Utilisation

Page de 335
Monitoring the Cajun Switch (Layer 2 & Layer 3)
Cajun P550/P220 Switch Operation Guide 
 16-3
2. Use Table 16-2 to set the threshold values:
Checking Active Alarms
Each switch stores a table of active alarms. This allows you to view a list of open issues in 
the switch without having to view the entire event log. By doing this, you can quickly 
obtain a snapshot of the switch’s health.
Viewing the Active Alarm Table
To view the Active Alarm Table in the Event Subsystem section of the Web Agent 
window, click Active Alarms. The Active Alarm Table opens.
Using the Event Subsystem
There are two switch system activity logs for Layer 3:
❒ Event Log - stores a large table of events. The size of the table is user-settable. 
Because these events are stored in switch memory, the list is cleared each time the 
switch reboots.
Table 16-2.  Temperature Thresholds 
Threshold
Defines...
 High Shutdown 
Temperature (Layer 2)/High 
Warning Temperature 
(Layer 3)
Value in degrees Celsius that when passed causes the switch to 
send a trap to the network management station and triggers a 
shutdown. By default, this value is 50 degrees Celsius. For the 
Layer 3 CPU sensor, the default value is 100 degrees Celsius.
Upper Warning 
Temperature
Value in degrees Celsius that when passed causes the switch to 
send a warning that the temperature is approaching the high 
temperature threshold. By default, this value is 45 degrees 
Celsius. For the Layer 3 CPU sensor, the default value is 85 
degrees Celsius.
Lower Warning 
Temperature
Value that in degrees Celsius that when passed causes the switch 
to send a warning that the temperature is approaching the low 
temperature threshold. By default, this value is 5 degrees 
Celsius.
Low Shutdown 
Temperature (Layer 2)/Low 
Warning Temperature 
(Layer 3)
How low the temperature must drop on the switch to reset the 
warning and high thresholds. This value prevents the switch 
from sending traps continually if the temperature is hovering 
around the threshold value. By default, this value is 0 degrees 
Celsius.