Avaya P550 Manuel D’Utilisation

Page de 335
Configuring the Cajun P550 Switch (Layer 2 & Layer 3)
3-24
Cajun P550/P220 Switch Operation Guide
5. From the Access pull-down menu, select a level for this community (Table 3-15). 
6. From the Security Level pull-down menu, select a security level for this 
community string (Table 3-16). 
7. From the Trap Receiver pull-down menu, select Enable.
8. Click APPLY to save your changes, or CANCEL to restore previous settings.
Changing the Console Serial Port Settings
You can use the Web Agent to change the communications settings for the serial port 
connection on the front panel of the Layer 3 supervisor module. 
Initially, the switch’s console port is configured as a TTY Console to support a TTY 
connection. The Layer 2 and Layer 3 supervisor modules allow you to reconfigure the 
console serial port as a PPP Console to support a dial-in PPP connection using a modem.
Note:  As a PPP console, you can change only the switch’s baud rate and flow control 
parameters. The flow control parameters are limited to None or Xon/Xoff.
Table 3-15.  Access Levels
Access Level
Manager Can...
Manager Cannot...
Read-Only
View switch configuration settings 
and statistics. 
View community strings. 
Change switch 
configurations.
Read-Write
View and set switch configuration 
settings, and view statistics.
View community strings.
Read-Write with 
Security Level Set 
to admin
View and set all switch parameters, 
including community table.
N/A
None
Do nothing. This selection allows 
you to disable a string without 
deleting it.
Access any switch 
features.
Table 3-16.  SNMP Security Levels
Option
Allows Access to...
normal
All switch configuration and reporting functions.
admin
All switch configuration and reporting functions, including 
access to community configuration.