Avaya P550 Guide De Référence
Logging
Cajun P550/P220 Command Line Interface Reference Guide
7-5
+
Change the number of syslog messages stored in the router's history table. The no form
of this command returns the number of messages to the default value, which is 512.
of this command returns the number of messages to the default value, which is 512.
Table 7-3.
Parameters, Keywords, Arguments
This example specifies that 1024 messages can be stored in the router’s history table.
Cajun(configure)#
logging history-size 1024
To Enable:
logging history size {128|512|1024|2048
To Disable:
[no] logging history size {128|512|1024|2048}
Name
Definition
128|512|1024|2048
The number of syslog messages stored in the router’s
history table. The choices are 128, 512, 1024, and
2048.
history table. The choices are 128, 512, 1024, and
2048.